background image

 

Item 

Requirements 

Result 

Temperature 

 

MSR3610-I-XS/3610-IE-XS/3610-I-DP/3610-IE-DP/36
10-IE-ES/3610-IE-EAD: 

 

Without a drive: 0°C to 45°C (32°F to 113°F). 

 

With a drive: 5°C to 40°C (41°F to 104°F). 

 

MSR3610-I-IG/3610-IE-IG: 

 

Without a drive: –20°C to +55°C (–4°F to +131°F) 

 

With a drive: 5°C to 40°C (41°F to 104°F)

 

 

Relative humidity 

 

Without a drive: 5% to 95%, noncondensing. 

 

With a drive: 10% to 80%, noncondensing.

 

 

Cleanliness 

 

Dust concentration ≤ 3 x 10

4

 particles/m

3

 

No visible dust on desk within three days. 

 

ESD prevention 

 

The device and floor are reliably grounded. 

 

Dust-proof measures are taken in the equipment room. 

 

Humidity and temperature are maintained at acceptable 
levels. 

 

An ESD wrist strap and ESD garment are available. 

 

An anti-static workbench and anti-static bags are 
available. 

 

EMI prevention  

 

Effective measures are taken for filtering interference 
from the power grid. 

 

The protection ground of the device is away from the 
grounding facility of power equipment or lightning 
protection grounding facility. 

 

The device is far away from radio transmitting stations, 
radar stations, and high-frequency devices. 

 

Electromagnetic shielding, for example, shielded 
interface cables, is used as required. 

 

Lightning 
protection 

 

The device is reliably grounded. 

 

The AC power receptacle is reliably grounded. 

 

(Optional.) Port lightning protectors are available. 

 

(Optional.) Power lightning protectors are available. 

 

(Optional.) Signal cable lightning protectors are 
available. 

 

Electricity safety 

The power-off switch in the equipment room is identified and 
accessible so that the power can be immediately shut off 
when an accident occurs. 

 

Workbench 

 

The workbench is stable. 

 

The workbench is reliably grounded. 

 

Rack 

 

The rack has a good ventilation system. 

 

The rack is sturdy and can support the device and its 
accessories. 

 

The rack has a size that can accommodate the device. 

 

A minimum clearance of 0.8 m (2.62 ft) is reserved 
between the rack and walls or other devices. 

 

Safety 
precautions 

 

The device is far away from any sources of heat or moisture. 

 

The emergency power switch in the equipment room is identified and 
accessible. 

 

Accessories 

 

Installation accessories supplied with the device are ready. 

 

User-supplied tools are ready. 

 

Reference 

 

Documents shipped with the device are available. 

 

Summary of Contents for MSR3610-I Series

Page 1: ...H3C MSR3610 I ICT Converged Gateway Series Installation Guide New H3C Technologies Co Ltd http www h3c com Document version 6W104 20201231...

Page 2: ...respective owners Notice The information in this document is subject to change without notice All contents in this document including statements information and recommendations are believed to be acc...

Page 3: ...ose syntax choices keywords or arguments that are optional x y Braces enclose a set of required syntax choices separated by vertical bars from which you select one x y Square brackets enclose a set of...

Page 4: ...s a Layer 2 or Layer 3 switch or a router that supports Layer 2 forwarding and other Layer 2 features Represents an access controller a unified wired WLAN module or the access controller engine on a u...

Page 5: ...Documentation feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments...

Page 6: ...12 Installing an M 2 SSD drive 13 Installing a SIC interface module 13 Installing a SATA drive 14 Connecting interface cables 15 Connecting an Ethernet copper port 15 Connecting an Ethernet fiber por...

Page 7: ...ii Solution 26 No response from the serial console port 26 Symptom 26 Solution 26 Interface module failure 26 Symptom 26 Solution 26...

Page 8: ...mage to hardware or software General safety recommendations Keep the device and installation tools away from walk areas Place the device in a dry and flat location and make sure anti slip measures are...

Page 9: ...change of materials and metal corrosion Lasting low relative humidity can cause washer contraction and ESD and cause problems including loose mounting screws and circuit failure High temperature can...

Page 10: ...e device uses left to right airflow for heat dissipation as shown in Figure1 1 Figure1 1 Airflow through the chassis MSR3610 I DP To ensure good ventilation follow these guidelines Maintain a minimum...

Page 11: ...ance coupling Electromagnetic wave radiation Common impedance including the grounding system coupling To prevent EMI use the following guidelines Take effective measures to filter interference from th...

Page 12: ...tem Requirements Result Installation site Ventilation A minimum clearance of 100 mm 3 9 in is reserved around the chassis The installation site has a good ventilation system Flat head screwdriver Phil...

Page 13: ...om radio transmitting stations radar stations and high frequency devices Electromagnetic shielding for example shielded interface cables is used as required Lightning protection The device is reliably...

Page 14: ...ct and if you want to open the chassis contact H3C for permission Otherwise H3C shall not be liable for any consequence The installation method is the same for the H3C MSR3610 I ICT converged gateways...

Page 15: ...s Optional Connect interface cables Optional Install a SATA drive Yes No Connect AC power cords Verify the installation Power on the device Troubleshoot the device Power off the device Operating corre...

Page 16: ...ice for heat dissipation Do not place heavy objects on the device To mount the device on a workbench 1 Place the device upside down on the workbench and attach the rubber feet to the four round holes...

Page 17: ...480 mm 18 90 in 360 mm 14 17 in for the chassis 60 mm 2 36 in for connecting AC power cords at the front 60 mm 2 36 in for connecting the E1 cable at the rear A minimum of 600 mm 23 62 in in depth rec...

Page 18: ...ne ear of a cage nut into the marked installation hole b Use a flat head screwdriver to push another ear into the same hole Figure2 4 Installing cage nuts 3 Applicable only to MSR3610 I IG and MSR3610...

Page 19: ...is crucial to lightning protection and EMI protection When you install and use the device first ground the device reliably Ensure a minimum resistance of 5 ohms between the device and the ground To c...

Page 20: ...llips screwdriver to screw the M 2 SSD drive into place Figure2 9 Installing an M 2 SSD drive Installing a SIC interface module CAUTION Only the SIC M2 SATA riser module is hot swappable Before instal...

Page 21: ...install a SATA drive 1 Push the drive slowly into the drive carrier with the golden plating on it facing downwards 2 Use the four fastening screws provided with the driver carrier to secure the drive...

Page 22: ...rnet port on the device Connect the other end of the cable to the Ethernet port on the peer device The fixed ports on the device are MDI MDIX autosensing You can use straight through or crossover netw...

Page 23: ...into any open optical fiber connector and a dust plug into any open fiber port or transceiver module port to protect them from contamination and ESD damage Make sure the Tx and Rx ports on a transcei...

Page 24: ...3 Use the power cord retainer clip to secure the power cord into place 4 Connect the other end of the AC power cord to an AC power source Figure2 15 Connecting an AC power cord for an MSR3610 I DP 361...

Page 25: ...r at one end of the PoE adapter into the device 2 Connect the other end of the PoE adapter to an AC power source Figure2 17 Connecting a PoE adapter Verifying the installation Verify the following ite...

Page 26: ...connector to the console port of the device Figure2 18 Connecting the console cable Setting configuration terminal parameters To configure and manage the device through the console port you must run...

Page 27: ...uns BootWare System is Starting Press Ctrl D to access BASIC BOOTWARE MENU Booting Normal Extend Bootware H3C MSR3610 BootWare Version 1 02 Copyright c 2004 2017 New H3C Technologies Co Ltd Compiled D...

Page 28: ...essing the power button when the device is operating Doing so will power off the device and cause service interruption IMPORTANT The barcode on the device chassis contains product information that mus...

Page 29: ...ly the SIC M2 SATA and SIC 5G interface modules are hot swappable Before replacing a SIC interface module except for the SIC M2 SATA and SIC 5G make sure the device is powered off Before removing a SI...

Page 30: ...of 45 degrees and then pull the drive slowly out of the M 2 slot on the SIC M2 SATA riser module Keep the removed M 2 SSD drive secure for future use 4 Install a new M 2 SSD drive For more information...

Page 31: ...he empty fiber port Figure3 5 Removing a transceiver module 4 Troubleshooting IMPORTANT The barcode on the device chassis contains product information that must be provided to local sales agent when y...

Page 32: ...sue persists contact H3C Support No display on the configuration terminal Symptom The configuration terminal does not have display when the device is powered on Solution To resolve the issue 1 Verify...

Page 33: ...he issue 1 Verify that the serial console cable is in good condition 2 Verify that the port settings are correct 3 If the issue persists contact H3C Support Interface module failure Symptom An interfa...