Interface Card and Interface Module Manual
H3C MSR 20/30/50 Series Routers
Chapter 3 Multifunctional Interface Modules
3-64
2) Symptom 2: The ACTIVE LED stays off when powering on the router.
Troubleshooting: When powering up the device, the ACTIVE LED should flashing for
two seconds before turning off, which indicates the encryption processor of the
MIM-HNDE module has been configured and is ready for work. If the ACTIVE LED
stays on when powering up the device, this means the initialization of the processor
fails and the system bus does not work normally. Check the connection between the
MIM-HNDE module and the host. If the connection is good, the abnormal status may
due to the host or the MIM-HNDE module, contact our agents for support.
3) Symptom 3: The ACTIVE LED stays on or off when the MIM-HNDE module is
running.
Troubleshooting: The ACTIVE LED should be blinking when the MIM-HNDE module
runs the encryption service. The solid on or off indicates the system bus works
abnormally. Check the connection between the MIM-HNDE module and host. If the
connection is good, the abnormal status may due to the host or the MIM-HNDE module,
contact our agents for support.
3.20 MIM-2VE1 Module
3.20.1 Introduction
2-port E1 voice interface module (MIM-2VE1) can handle dense voice signals in VoIP
system. It provides two CE1/PRI/R2 ports, allowing the access of 60 channels of voice
signals.
Note:
z
VCPM is provided to users together with MIM-2VE1. Users can select VPM module
as needed.
z
VPM module is installed on the main board of MIM-2VE1.
3.20.2 Interface Attributes
The interface attributes of MIM-2VE1 are given in the following table.
Table 3-42
Interface attributes of MIM-2VE1
Attribute
Description
Connector DB-15
Number of connectors
2