Installation site examination 

The installation environment for the access controller module must meet the 
temperature and humidity, and cleanness requirements described in the 

H3C 

LSQM1WCMB0 Access Controller Module Installation Guide

 

EMI prevention 

All interference sources, from the outside or inside of the switch and application system, 
adversely affect the access controller module in the conduction patterns of 
capacitance coupling, inductance coupling, electromagnetic wave radiation, and 
common impedance (including grounding system) coupling, and cable conduction 
(including power cables, signal cables and output cables).  

To prevent interference: 

 

 

Take effective measures against interference from the power grid. 

 

Keep the protection ground (PGND) of the switch as far away as possible from the 
grounding device or lightning protection grounding device of the power supply 
equipment.  

 

Keep the switch far away from high-power radio launchers, radars, and equipment 
with high-frequency and high current. 

 

Use electromagnetic shielding when necessary. 

Grounding requirements 

A good grounding system is essential for lightning protection, interference prevention 
and ESD prevention to ensure the stable and reliable operation of the switch and the 
access controller module. 

 

Installation tools and meters 

When installing the access controller module, you may need the tools listed in 

Table 1

 . 

These installation tools and meters are not shipped with the LSQM1WCMB0.  

Table 1 

List of installation tools and meters 

Type 

Tools 

Fastening tools

 

Phillips screwdrivers

 

Special tools

 

ESD-preventive wrist strap

 

Fiber cleaning tools

 

Airlaid paper, fiberscope

 

Meters

 

Multimeter, 500V Megohmmeter (for 
measuring insulation resistance), earth 
resistance tester

 

Summary of Contents for LSQM1WCMB0

Page 1: ...uick Start Guide Abstract This document provides steps for the basic installation of the LSQM1WCMB0 access controller module for the H3C S7502E S7503E S7506E S7506E V S7510E Ethernet switches Hangzhou...

Page 2: ...press or implied Hangzhou H3C Technologies Co Ltd and its licensors shall not be liable for technical or editorial errors or omissions contained herein Acknowledgments H3C Aolynk H3Care TOP G IRF NetP...

Page 3: ...nation 5 Installation tools and meters 5 Hardware installation 6 Console cable connection 6 Removing and installing the LSQM1WCMB0 7 Initial startup of the access controller module 8 Setting up a conf...

Page 4: ...ce to implement the wireless access control functionality The LSQM1WCMB0 access controller module starts working as soon as it is installed into a slot of a switch Installation preparations This secti...

Page 5: ...ar away as possible from the grounding device or lightning protection grounding device of the power supply equipment Keep the switch far away from high power radio launchers radars and equipment with...

Page 6: ...ble connection The console cable is an 8 core cable with an RJ 45 connector at one end for the console port of the LSQM1WCMB0 and a DB 9 female connector at the other end for the 9 pin serial port of...

Page 7: ...ector Removing and installing the LSQM1WCMB0 This section describes how to remove and install the LSQM1WCMB0 module This module is hot swappable Removing the LSQM1WCMB0 1 Face the front side of the sw...

Page 8: ...ting the console cable 1 Connect the DB 9 female connector of the console cable to the serial port of the PC 2 Connect the RJ 45 connector of the console cable to the console port of the LSQM1WCMB0 mo...

Page 9: ...console cable is correctly connected the console terminal or PC is running and the terminal parameters are properly set Powering on the access controller module After power on of the LSQM1WCMB0 the co...

Page 10: ...n more about access controller software maintenance see H3C Access Controller Modules Software Upgrade Guides Configuration For details on configuring your module see the H3C WX Series Access Controll...

Reviews: