background image

 

Connecting the console cable 

Connect the console cable before configuring the LSQM1WCMB0 using a console 
terminal device (such as a PC):

 

1.

 

Connect the DB-9 female connector of the console cable to the serial port of the 
PC.  

2.

 

Connect the RJ-45 connector of the console cable to the console port of the 
LSQM1WCMB0. Be sure to plug the cable into the correct port.  

 CAUTION: 

When the LSQM1WCMB0 is powered on, H3C recommends using the following order when 
connecting or disconnecting the console cable:  

 

When connecting the LSQM1WCMB0 to a PC, first connect the DB-9 connector of the console 
cable to the PC and then connect the RJ-45 connector to the LSQM1WCMB0.  

 

When removing the connection, first unplug the RJ-45 connector and then unplug the DB-9 
connector.  

Removing and installing the LSQM1WCMB0 

This section describes how to remove and install the LSQM1WCMB0 module. This module is hot 
swappable.  

Removing the LSQM1WCMB0 

1.

 

Face the front side of the switch.  

2.

 

Using a Philips screwdriver, loosen the captive screws on the access controller 
module.  

3.

 

Simultaneously pivot the ejector levers of the access controller module away from 
the front panel to detach the board from the backplane.  

4.

 

Gently pull the access controller module out of the slot along the guide rails.  

5.

 

If the slot is to remain empty, install a blank filler panel to prevent dust from getting 
into the switch chassis and ensure good ventilation.  

Installing the LSQM1WCMB0 module 

1.

 

Face the front side of the switch.  

2.

 

Choose an empty slot and remove the blank filler panel.  

3.

 

Push the access controller module into slot along the guide rails until the positioning 
hole of the board is seated onto the positioning pin on the backplane.  

Summary of Contents for LSQM1WCMB0

Page 1: ...uick Start Guide Abstract This document provides steps for the basic installation of the LSQM1WCMB0 access controller module for the H3C S7502E S7503E S7506E S7506E V S7510E Ethernet switches Hangzhou...

Page 2: ...press or implied Hangzhou H3C Technologies Co Ltd and its licensors shall not be liable for technical or editorial errors or omissions contained herein Acknowledgments H3C Aolynk H3Care TOP G IRF NetP...

Page 3: ...nation 5 Installation tools and meters 5 Hardware installation 6 Console cable connection 6 Removing and installing the LSQM1WCMB0 7 Initial startup of the access controller module 8 Setting up a conf...

Page 4: ...ce to implement the wireless access control functionality The LSQM1WCMB0 access controller module starts working as soon as it is installed into a slot of a switch Installation preparations This secti...

Page 5: ...ar away as possible from the grounding device or lightning protection grounding device of the power supply equipment Keep the switch far away from high power radio launchers radars and equipment with...

Page 6: ...ble connection The console cable is an 8 core cable with an RJ 45 connector at one end for the console port of the LSQM1WCMB0 and a DB 9 female connector at the other end for the 9 pin serial port of...

Page 7: ...ector Removing and installing the LSQM1WCMB0 This section describes how to remove and install the LSQM1WCMB0 module This module is hot swappable Removing the LSQM1WCMB0 1 Face the front side of the sw...

Page 8: ...ting the console cable 1 Connect the DB 9 female connector of the console cable to the serial port of the PC 2 Connect the RJ 45 connector of the console cable to the console port of the LSQM1WCMB0 mo...

Page 9: ...console cable is correctly connected the console terminal or PC is running and the terminal parameters are properly set Powering on the access controller module After power on of the LSQM1WCMB0 the co...

Page 10: ...n more about access controller software maintenance see H3C Access Controller Modules Software Upgrade Guides Configuration For details on configuring your module see the H3C WX Series Access Controll...

Reviews: