h/p/cosmos motion stair 600 User Manual Download Page 8

 

User manual motion stair 600

 med/600 

Version 3.0 

Page 

8

 of 

19

 

4.7

 

DOT Matrix 

In  the lower half of the LCD display a text guides through the programming menu in the chosen language in 
order to ease the programming. Additionally, the wattage and pulse paths are visualized during workouts.The 
curve  for  the  wattage  is  displayed  constantly  whereas  the  pulse-curve  flashes.  The  display  depends  on  the 
program but pressing the scan button can alternate the display.  
List of graphical display options: 

 

Standard – shows an excerpt of the last 5 minutes of the workout. 

 

Overview – shows the complete workout up to 50 minutes 

 

Figures – super size display of wattage and pulse 

 

Profile – shows the impact profiles 

 

Zone  –  display  especially  designed  for  the  pulse-dominated  programs.  Here,  the  target  heart  rate  is 
shown together with the actual heart rate 

 

Test  –  This  option  visualizes  the  pulse  movements  during  the  test  and  shows  the  heart  rate  actually 
reached at the end of the test. 

 

Pulse – the actual signals are shown like an oscillograph.

 

4.8

 

Biofeedback 

The  Biofeedback  function  enables  the  user  to  get  information  through  a  colour  indication  he  is  training 
according to the specifications. The background colour blue informs that one isn´t training in the optimal range. 
It´s possible that one is still warming up or training with too little rpm/heart rate. 

 

The background colour green shows that the user is training in the optimal training range.  
Red  informs  that  target  values  are  undershot  or  exceeded.  In  the  pulse  controlled  workouts  the  load  will  get 
reduced  if  the  target  heart  rate  gets  exceeded.  In  other  programs  the  rpm  can  be  the  value  that  the  colours 
refer to. 

 
 
 
 
 
 
 
 

Fig.4: Multicolor backlight function for a visual indication of workout target. 

4.9

 

Training Control via the storage media 

The storage media has a standard fitting in all units of the cardio line. Workout control via the storage media

 

is 

a means of easing the handling of the unit. The storage media

 

system supports the user in all aspects of training 

activities.  
The system consists of a monitor unit with the storage media reader. The slot used to enter the media is located 
on  the  right  side  of  the  monitor  casing.  An  acoustical  signal  proves  the  acceptance  of  the  storage  media.  The 
storage  media  system  makes  training  with  all  units  of  the  cardio  line  easier  and  more  efficient.  The 
programming of the media can be done directly on the ergometer. The results will then only be shown in the 
unit display.  
The  planning  of  training  can  alternatively  be  done  with  PC  Software.  If  the  software  is  used,  the  individual 
training programs are transferred to the storage media. All results are saved on the storage media

 

and can be 

analysed on the PC after the results have been transferred.  
Optionally the usage of the unit can get  restricted to storage media use only. This function  can get chosen in 
the secret menu with the following alternatives: Usage solely with storage media; if not using a storage media 
solely the Quick Start program is possible; usage with and without storage media possible. The default value is 
using the machine with and without storage media. Please contact your dealer for necessary settings in case you 
want to restrict the usage of the machines. 

 

 

Programming Training Schedules manually onto the member media 

 

 

One must get onto the ergometer and begin pedalling or activate the display by pressing any button. 

 

The individual data for the desired program has to be entered manually on the monitor. The program 
then starts. 

 

The trainer media is entered into the slot once the display shows GO until an acoustical signal indicates 
that the media has been recognized. 

 

The  member  media  gets  inserted.  Now  the  maximum  number  of  workouts  (1-255)  can  get  chosen. 
Confirm with ENTER. When the acoustic signal rings out, the data has been saved and the member card 
is functioning. Selecting 255 workouts equals no limit. 

/H-p-cosmos.local/dfs/erp$/article/cos30021ef-med600/manual/EN/20170926_cos30033ef-med600-ef-600_torqualizer_stair_instructions_for_use_EN.pdf

Summary of Contents for motion stair 600

Page 1: ...00 Version 3 0 Page 1 of 19 User manual for the motion stair 600 med and the motion stair 600 H p cosmos local dfs erp article cos30021ef med600 manual EN 20170926_cos30033ef med600 ef 600_torqualizer...

Page 2: ...12 Programs of the cardio line 10 4 13 Pulse controlled programs 15 4 14 PC Interface 15 5 Maintenance 16 5 1 Instructions for the error condition detection failure 16 5 2 Instructions for preventive...

Page 3: ...tandard DIN EN ISO 20957 1 and DIN EN ISO 20957 5 usage class S commercial use gyms of the accuracy class A 10 and designed to suit the needs of fitness gyms and preventive fitness The items of the ca...

Page 4: ...e not sure ask a supervisor Before the start of the workout it must be assured that no one is close to moving parts to avoid danger for a third person Above all hold unattended children off the units...

Page 5: ...y can be equipped with a Polar hand pulse system combined with a coded wireless signal transmitter With this technology two advanced measuring systems work together The hand pulse measurement has prio...

Page 6: ...a if the workout has been started using a storage media The Scan button changes the display mode parameters or graphical displays within the Dot Matrix on the monitor The Smart Key buttons function as...

Page 7: ...alories burned or the remaining calories to be burned are shown Level Display of the actual intensity 1 21 Storage media The symbol for the storage media appears whenever a member card is inserted int...

Page 8: ...the handling of the unit The storage media system supports the user in all aspects of training activities The system consists of a monitor unit with the storage media reader The slot used to enter th...

Page 9: ...r four seconds each After that the personal workout that was previously saved on the storage media is being started automatically and the workout session can begin The storage media can be removed aft...

Page 10: ...x x x x 5 Isokinetik 6 Therapy x x x X 7 Interval x x 8 K cal x x x x 9 Hill x x x 10 Random x 11 Distance x x x Tab 1 Programs of the cardio line med separated by units usage and biofeedback program...

Page 11: ...le By doing so the user can perform a so called cross training whereby the resistance is adjusted to the expected wattage during the workout and the ergometer will simply make fine tunings to the resi...

Page 12: ...cates the hill profile remaining and the actual position during the workout The intensity will be shown permanently as level or as wattage speed The heart frequency is shown if the trainee is using on...

Page 13: ...this symbol you start and end the programming of an interval sequence Stepless load increase through the time of the sequence Increasing by steps Finish of the interval programming symbol request of s...

Page 14: ...doesn t get used by an individual In this case you can ignore the results The display shows writing Program for some seconds The program is now stored on the media The storage media can now be used A...

Page 15: ...e as well as intensity alongside the recovery progress As a general rule intensity changes occur by increasing the workload e g increasing of the wattage At the therapy training the intensity gets var...

Page 16: ...for damages and tightness In general Clean the devices with mild purifier and a wet cloth to get off aggressive sweat Dry the device afterwards The usage of spray bottles is not allowed it has shown...

Page 17: ...ed control According to the transposition of the medical device directive 93 42 EEC into national law At elliptical and stairclimbing machines cross and stair Metrological Controls are not required by...

Page 18: ...cedures are possible 1 The service is conducted on site by our service employees 2 The required spare part s are shipped 3 An exchange unit is arranged and sent to the user The defective parts must be...

Page 19: ...ness GmbH Co KG Trippstadter Str 68 67691 Hochspeyer Germany Tel 49 0 6305 71499 0 Fax 49 0 6305 71499 111 info emotion fitness de www emotion fitness de H p cosmos local dfs erp article cos30021ef me...

Reviews: