3.3

 

Indications and contraindications  

Indications

 

 

Mobility of the locomotors apparatus 

 

Strengthening of the muscles 

 

Strengthening of the cardiovascular system

  

Contraindications 

 

 

Cardiovascular affections 

 

Pains of the locomotors apparatus 

 

During workout 

 

Pains in the thoracic region 

 

Nausea 

 

Dizziness 

 

Pain in the joints involved in the motion

 

When taking medication ask for a doctor’s training advice.   

 

4

 

Operating the display 

Depending on the program version chosen, three or eleven training programs and eventually the optional test 
programs allow for an individual and diversified training. 
Depending  on  the  program  version  chosen,  three  or  nine  training  programs  and  eventually  the  optional  test 
programs allow for an individual and diversified training.  
 

4.1

 

Pulse systems 

Every piece of equipment of the cardio line includes the original Polar Pulse System, which receives signals from 
a  breast  belt  by  the  exerciser  (the  breast  belt  is  not  included  in  the  delivery  of  the  equipment).  The  wireless 
transmission to the electric display is coded. The Polar

©

 technology is based on a magnetic field, which transfers 

the  signals.  This  magnetic  field  can  be  interfered  by  several  sources.  The  most  common  reason  is  the  use  of 
breast  belts  that  are  not  100%  compatible  with  the  Polar

©

-System  and  commonly  have  a  longer  range.  Cell 

phones, speakers, TVs, power lines, fluorescent tubes, and motors with high power can also interfere with the 
Polar

©

 Pulse System. 

The measuring of the pulse frequency is ECG precise. Only when using coded breast belts, like T31C, the heart 
rate gets transferred coded. When using an uncoded breast belt, like T31, the transfer is uncoded. 

 

 
 
 

 
 
Hand pulse (optional – solely for units of the fitness line)

 

As an option, all units of the cardio line (fitness), excluding the body, can be equipped with a Polar

©

 hand pulse 

system  combined  with  a  coded  wireless  signal  transmitter.  With  this  technology,  two  advanced  measuring 
systems work together. The hand pulse measurement has priority over the wireless signal. When all 4 sensors are 
touched,  a  hand  symbol  becomes  displayed  on  the  monitor.  Approximately  10  seconds  later,  the  digital 
frequency display appears.  
Please note, that cold dry hands, but also hands with lotion influence the measurement negatively. Because of 
those reasons the hand pulse only works for about 95% of the users. In general, the hand pulse is not advisable 
for tests and pulse controlled training. Machines with medical certification cannot be offered with this feature.

 

 
Ear-pulse (optional)

 

The  ear-pulse-system  with  the  optical  measuring  at  the  earlobe  is  available  as  an 
option.  If  an  ear-pulse  cable  is  connected  it  has  priority  over  Polar

© 

pulse 

measurement, 

which 

will 

get 

disconnected. 

Attention: 

Rub 

earlobe 

thoroughly before applying the ear sensor. To check proper operation of the sensor, 
switch  to  the  pulse  display  for  surveillance.  Therefore  press  the  Scan-button  three 
times while exercising. The indication for the pulse signals has to be high and at regular intervals.

 

 

 

Multi-colour-backlight

 

All ergometers are equipped with a multicolour backlight for the LCD-Display. The electricity gets provided by 
the brake. The brightness depends on the current load. Lighting is not possible with really low load  because the 
required power can´t get provided safely. The backlight of the ergometer  turns on after  some  seconds in use. 
Due to the backlight it´s easier to read the display, even if lighting conditions are bad. 

Safety advice according to DIN EN ISO 20957

 

Warning!  Systems  for  the  heart  rate  surveillance  can  be 
faulty.  Excessive  workouts  can  lead  to  serious  physical 
damage  or  death.  Abort  the  workout  immediately  when 
dizziness or nausea occurs. 

 

/H-p-cosmos.local/dfs/erp$/article/cos30021ef-med600/manual/EN/20170926_cos30033ef-med600-ef-600_torqualizer_stair_instructions_for_use_EN.pdf

Summary of Contents for motion stair 600

Page 1: ...00 Version 3 0 Page 1 of 19 User manual for the motion stair 600 med and the motion stair 600 H p cosmos local dfs erp article cos30021ef med600 manual EN 20170926_cos30033ef med600 ef 600_torqualizer...

Page 2: ...12 Programs of the cardio line 10 4 13 Pulse controlled programs 15 4 14 PC Interface 15 5 Maintenance 16 5 1 Instructions for the error condition detection failure 16 5 2 Instructions for preventive...

Page 3: ...tandard DIN EN ISO 20957 1 and DIN EN ISO 20957 5 usage class S commercial use gyms of the accuracy class A 10 and designed to suit the needs of fitness gyms and preventive fitness The items of the ca...

Page 4: ...e not sure ask a supervisor Before the start of the workout it must be assured that no one is close to moving parts to avoid danger for a third person Above all hold unattended children off the units...

Page 5: ...y can be equipped with a Polar hand pulse system combined with a coded wireless signal transmitter With this technology two advanced measuring systems work together The hand pulse measurement has prio...

Page 6: ...a if the workout has been started using a storage media The Scan button changes the display mode parameters or graphical displays within the Dot Matrix on the monitor The Smart Key buttons function as...

Page 7: ...alories burned or the remaining calories to be burned are shown Level Display of the actual intensity 1 21 Storage media The symbol for the storage media appears whenever a member card is inserted int...

Page 8: ...the handling of the unit The storage media system supports the user in all aspects of training activities The system consists of a monitor unit with the storage media reader The slot used to enter th...

Page 9: ...r four seconds each After that the personal workout that was previously saved on the storage media is being started automatically and the workout session can begin The storage media can be removed aft...

Page 10: ...x x x x 5 Isokinetik 6 Therapy x x x X 7 Interval x x 8 K cal x x x x 9 Hill x x x 10 Random x 11 Distance x x x Tab 1 Programs of the cardio line med separated by units usage and biofeedback program...

Page 11: ...le By doing so the user can perform a so called cross training whereby the resistance is adjusted to the expected wattage during the workout and the ergometer will simply make fine tunings to the resi...

Page 12: ...cates the hill profile remaining and the actual position during the workout The intensity will be shown permanently as level or as wattage speed The heart frequency is shown if the trainee is using on...

Page 13: ...this symbol you start and end the programming of an interval sequence Stepless load increase through the time of the sequence Increasing by steps Finish of the interval programming symbol request of s...

Page 14: ...doesn t get used by an individual In this case you can ignore the results The display shows writing Program for some seconds The program is now stored on the media The storage media can now be used A...

Page 15: ...e as well as intensity alongside the recovery progress As a general rule intensity changes occur by increasing the workload e g increasing of the wattage At the therapy training the intensity gets var...

Page 16: ...for damages and tightness In general Clean the devices with mild purifier and a wet cloth to get off aggressive sweat Dry the device afterwards The usage of spray bottles is not allowed it has shown...

Page 17: ...ed control According to the transposition of the medical device directive 93 42 EEC into national law At elliptical and stairclimbing machines cross and stair Metrological Controls are not required by...

Page 18: ...cedures are possible 1 The service is conducted on site by our service employees 2 The required spare part s are shipped 3 An exchange unit is arranged and sent to the user The defective parts must be...