9
GYSFLASH 9.24
EN
TROUBLESHOOTING
Symptoms
Causes
Solutions
1 Indicator
blinks.
• Polarity reversal
• Battery voltage is too high
• Clamps in short-circuit
• Check that the clamps are properly connected.
• Check that the selected voltage matches the
battery voltage (6, 12 or 24V).
2 Indicator
is on.
Charge failure, battery non recoverable. Change the battery and press
to restart a
charge.
3
Indicator
stays on even after pressing
the
button.
Thermal protection.
Ambient temperature is too high (>50°C), cool the
room and let the charger cool down.
4 Indicator blinks.
Charger in sleep mode.
Press button
or connect a battery to the char-
ger to exit sleep mode.
5 Indicator stays on.
Charge interrupted by pressing
button.
Press
again to restart the charge.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported