GVS KI/U 0401.1 User Manual Download Page 45

K-BUS

®

KNX/EIB

Universal Interfaces

42

5.2.6. Parameter window “Indicate object In and Out, X”

The parameter window “Indicate object in and out, X” will be shown in Fig. 21, the LED is used to

indicate the input and output of the communication object.

Fig.21 Parameter window “Indicate object in and out, X”

Parameter “LED on time”

This parameter defines the indicative time of LED when there is input or output of communication

object, which means the switch on time.Options:

100ms

200ms

……

60s

Summary of Contents for KI/U 0401.1

Page 1: ...K BUS Universal Interfaces 4 fold_V1 1 KI U 0401 1 KNX EIB Home and Building Control System User Manual ...

Page 2: ...ces away from strong magnetic field high temperature wet environment 2 Do not fall the device to the ground or make them get hard impact 3 Do not use wet cloth or volatile reagent to wipe the device 4 Do not disassemble the devices ...

Page 3: ...rameter window Multiple operation X 29 5 1 9 Parameter window Shutter control X 32 5 2 Description of setting parameter in part of LED channel 36 5 2 1 Parameter window Flashing X 36 5 2 2 Parameter window Switch X 38 5 2 3 Parameter window Control by Input X 39 5 2 4 Parameter window Indicate Object In X 40 5 2 5 Parameter window Indicate Object Out X 41 5 2 6 Parameter window Indicate object In ...

Page 4: ...stic appliance indirectly At the same time they also enable the control of LEDs The extremely compact design enables the device to be inserted in a conventional 80mm or 86mm wiring box The Universal Interfaces connect to the bus though the KNX connection terminals and have no use for additional supply voltage It is available to assign the physical address and set the parameters by Engineering desi...

Page 5: ...t circuit proof overload protection reverse voltage protection Operating and display Programming LED and button For assignment of the physical address Green LED flashing Indicate the application layer running normally Connections Input output 2 5 pin cables approx 30 cm long can be extended to max 10 m KNX via bus connecting terminal Temperature Operation 5 C 45 C Storage 25 C 55 C Transport 25 C ...

Page 6: ...IB Universal Interfaces 3 Chapter 3 Dimension and Connection diagram 3 1 Dimension diagram 3 2 Connection diagram 1 KNX bus connection terminal 4 LED terminal 2 Programming LED 5 KEY terminal 3 Programming button ...

Page 7: ...ing the states of several actuator groups The actuator groups can either be controlled via max 5 individual objects or via an 8 bit scene object Switching sequence For the operation of several actuator groups in a preselected sequence e g the latching relay Counter For counting input pulses Various data types of the counter can be set It is able to set the counting rate whether to sending the curr...

Page 8: ...ption of setting parameter in part of device channel 5 1 1 Parameter window General Setting Parameters for the functions which affect the complete device can be set via the Fig 1 Fig 1 parameter window General Setting Parameter Limit number of Tele It is use to limit the number of sending telegrams to decrease the burthen of bus It is possible to set how many telegrams can be sent within an adjust...

Page 9: ... be shown in Fig 2 and Fig 4 Fig 2 do not distinguish between long and short operation while Fig 4 opposite Fig 2 Parameter window Switch X do not distinguish between long and short operation Parameter function of the channel The parameter determines the function option in the channel the current option is switch If No function is selected it means the channel is disabled Options No function Switc...

Page 10: ...e following drawing clarifies the function Options No Yes Note The long operation in the below chapters are the same with here Parameter Cyclic send Tele Tele Switch This parameter is visible if there is no distinction between a short and long operation It is able to set whether to send the current value of object Tele Switch X cyclically on the bus Options No Always If switch off If switch on If ...

Page 11: ...meter is used to set the interval time between two telegrams that are sent cyclically it is visible if cyclical sending has been set Transmission cycle time Base Factor Base options 1s 10s 1h Factor options 1 255 Parameter Send object value after voltage recovery if yes not equal toggle It can be set whether to send the value of the object Tele Switch X on the bus after voltage recovery this param...

Page 12: ...tch X in channel A Then the priority of channel B is higher then it s C the last is D The priority of LED X in function channel in the device is higher than the LED X channel the LED X can not be implement any operation in channel LED X which is used in the function channel in the device If the parameter LED function is set LED A accord to switch value or LED A toggle by switch value options the o...

Page 13: ...he effective time of the contact operation is Base Factor Base options 100ms 1min Factor options 1 255 Note The parameter window and the explanation of parameter Min operation in the Debounce time in the below chapters are the same with here Fig 4 Parameter window Switch X distinguish between a short and long operation ...

Page 14: ...ation When the button operation is confirm to a short or a long operation the object value will be update immediately Options No action Off On Toggle Parameter Long operation after Base Factor This parameter is visible if there is a distinction between a short and long operation The period TL is defined here after which an operation is interpreted as long TL Base Factor Base options 100s 1s 1h Fac...

Page 15: ...or a normally closed contact Options Normally closed Normally open The parameter introduced in this chapter is use Normally open as the example the normally close is just opposite Parameter Dimming functionality This parameter determines whether the lighting is only dimmed or whether it should also be switched Options Dimming and switching Only dimming If the parameter Only dimming is selected the...

Page 16: ...ng functionality It is able to set a dim brighter or a dim darker after a long operation Options Dimming brighter Dimming darker Dim brighter darker with start brighter Dim brighter darker with start darker The parameter Dim brighter darker with start darker is selected it can be dim brighter or dim darker after a long operation it is just dim darker first and the latter operation negate Note The ...

Page 17: ...ming it begins the dimming process with a dim darker or brighter telegram and ends the dimming process with a stop telegram Cyclical sending of the dimming telegram is not required in this case If Step dimming is selected the dimming mode is step dimming the dimming telegram is sent cyclically during a long operation Once the operation has finished a stop telegram ends the dimming process Paramete...

Page 18: ...n A minimum operation time can only be set if the value Only dimming has been set in the parameter Dimming functionality The parameter window will be shown in Fig 3 5 1 4 Parameter window Value force output X Parameter window Value force output X will be shown in Fig 6 and Fig 7 in Fig 6 there is a distinction between a short and long operation while in Fig 7 is just opposite Fig 6 Parameter windo...

Page 19: ...ample the normally close is just opposite Parameter Distinction between long and short operation This parameter sets whether the input distinguishes between a short and long operation If yes is selected there is a waiting period after the opening closing of the contact to determine whether the operation is long or short Options No Yes Parameter Reaction on operation This parameter is visible if th...

Page 20: ...n The period TL is defined here after which an operation is interpreted as long TL Base x Factor Base options 100s 1s 1h Factor options 2 255 Parameter Send object value after voltage recovery This parameter defines whether to send object value of Tele Value X on the bus after the voltage recovery This parameter is visible if there is no distinction between a short and long operation If yes is sel...

Page 21: ...meter window Scene control X will be shown in Fig 8 it will be visible when the function channel Scene control is selected This function enables the states of several actuator groups to be recalled and stored Fig 8 Parameter window Scene control X Fig 9 Parameter window 8 bit scene ...

Page 22: ...of the actuator these 5 objects parameter window will be shown in Fig 10 If the parameter 8 bit scene is selected it can control the scene such as the scene function in dimming actuator switch actuator the parameter window will be shown in Fig 9 Parameter No of scene 0 63 This parameter will be visible when the scene control is 8 bit scene it can be set the No of scene The No range is 0 63 Paramet...

Page 23: ...lue 1 the object values Output 1bit 8bit group A E are read out via the bus While the object value is 1 the objects Output 1bit 8bit group A E can be modified via the bus On receipt of the object value 0 the current object values can t be modified On long operation and object value 1 If the object Store scene X receives the value 1 on the bus on the next long operation the object Output 1bit 8bit ...

Page 24: ...ending of a save command via the object 8 bit scene the current scene will be saved When the object store scene X receives the value 0 end up the saving the value of current scene Provided that a 1 has not been received at the object Store scene since the last save a long operation is interpreted in the same way as a short operation Parameter Long operation after This parameter is visible when the...

Page 25: ...ct or an 8 bit object Options 1 bit object 8 bit object Parameter Preset value actuator group A E This parameter set the preset value of the actuator group This value can be modified via the bus when save the scene If the bus voltage recovery this value will be modified as preset value 5 1 6 Parameter window Switching sequence X The parameter window Switching sequence will be shown in Fig 11 It is...

Page 26: ...level For example parameter 3level means there are 3 communication objects level 1 level 2 level 3 The first operation modified the value of level 1 the second operation modified the value of level 2 the third operation modified the value of level 3 the fourth from modified the value of level 3 the switch sequence is 000 001 011 111 011 The data send on the bus is the value of the communication ob...

Page 27: ...quentially on off several push buttons It can be set whether an operation of the push button switches up or down a level Options Switch upwards Switch downwards The implement direction of the parameter Switch upwards is 000 001 011 111 the implement direction of the parameter Switch downwards is 111 011 001 000 After the bus voltage recovery the current value is 000 if the parameter Switch downwar...

Page 28: ...s but otherwise operate independently of each other The counter always has the same data width as the differential counter The function is similar with the differential counter and the standard counter The difference is the differential counter can reset the counter value count from 0 and overflow by the bus counter report Attention When disable the function both key scanning and object in out are...

Page 29: ...hannel in the device is higher than the LED X channel the LED X can not be implement any operation in channel LED X which is used in the function channel in the device If the parameter LED status on pulse detection is set LED A ON or LED A OFF options the operation had been set in LED A can not be carry out Parameter Date width of counter The data type of the counter absolute counter and different...

Page 30: ...overy This parameter defines whether to send the current value when the bus voltage recovery If the differential counter has been enabled it is also sent on the bus and it is reset to zero If the bus voltage failure the standard counter and the differential counter are reset to the starting value the standard counter will calculate from the preset starting value Options No Yes Parameter Enable add...

Page 31: ...ntial counter should be increased by in the event of a counting pulse Range 32768 32767 Parameter Send counter value cyclically This parameter defines whether to send the current value cyclically If this parameter has the value Yes the values of the counter and the differential counter are sent cyclically on the bus Options No Yes Parameter Base Factor 1 255 It is visible if the parameter Send cou...

Page 32: ...on for the differential counter is from 0 to 32768 when the factor is positive counting forward the count direction for the standard counter is from 2500 to 32767 the count direction for the differential counter is from 0 to 32767 The counting rule is similar between the differential counter and the standard counter The difference is that the differential counter can set the overflow value When th...

Page 33: ...oduced in this chapter is use Normally open as the example the normally close is just opposite Parameter Max number of operations Num of objects This parameter specifies the maximum permitted number of operations This number is identical to the number of communication objects Output X fold Options Single operation 2 fold operation 3 fold operation 4 fold operation Parameter Value send object Tele ...

Page 34: ...rent value will be send on the bus until the last operation delay the delay time is the interval time between two operations Parameter Max time between two operation This parameter sets the interval between two operations If there are no further operations within this period the object output 1 fold is sent again Options 0 3s 0 5s 10s Parameter Additional object for long operation This parameter d...

Page 35: ...eter Debounce time It can set the vibration time to prevent unwanted multiple operation by bouncing of contacts in vibration time which means the effective time of the contact operation Options 10ms 20ms 150ms 5 1 9 Parameter window Shutter control X The parameter window Shutter control X will be shown in Fig 15 It is visible if the channel function Shutter control is selected When enable this fun...

Page 36: ...ion Alternate implement Move up or Move down operation alternate send the value of the object 0 and 1 1 push button short moving long stepping Short operation Alternate implement Move up or Move down operation alternate send the value of the object 0 and 1 Long operation Alternate implement Stop Adjust upward or Stop Adjust downward operation alternate send the value of the object 0 and 1 1 push b...

Page 37: ... is identical to the value that the operation starting Parameter Tele STOP adjust adj Cyclical send It is visible if the shutter control type is 1 push button short moving long stepping and 2 push button stepping It is able to set the interval time of sending the object stop adjust adj cyclical Options 0 3s 0 5s 10s Parameter Reaction on short operation It is visible if the shutter control type is...

Page 38: ...ype is move up and down the last control type is stop reaction Options Move up Move down Options Stop adjust up Stop adjust down Parameter Long operation after This parameter is visible if long operation activate The period is defined here after which an operation is interpreted as long Options 0 3s 0 5s 10s Parameter Debounce time It can set the vibration time to prevent unwanted multiple operati...

Page 39: ...Flashing X The parameter window will be shown in Fig 16 It is able to set the LED flash function and turn on the LED for long time simultaneously Fig 16 Parameter window Flashing X Parameter Function of the LED channel This parameter defines the function of the LED channel The default parameter is Flashing function If No action is selected it means this channel disable Options No action Flashing S...

Page 40: ...It is defines the time of LED flashing Base Factor Base options 1s 10s 1h Factor options 1 255 Parameter Send status by object Tele Status This parameter defines whether to send the LED status report on the bus Options No Yes If Yes is selected the object Send its status X will send value 1 when LED flashing it will send value 0 when LED stop flashing Parameter State of LED on bus voltage recovery...

Page 41: ...r LED is switch ON if This parameter defines the mode to switch on the LED Options Object Tele Switch 0 Object Tele Switch 1 Parameter Time limit of LED control This parameter defines whether to enable the function to restrict the time to switch on the LED Options No Yes Parameter Time limit Base Factor This parameter is visible if the time limit is active It is defines the time of LED flashing Ba...

Page 42: ...ts status X will send value 1 when LED switch on it will send value 0 when LED switch off Parameter State of LED on bus voltage recovery It is defines the state of LED when the bus voltage recovery Options On Off 5 2 3 Parameter window Control by Input X The parameter window Control by input X will be shown in Fig 18 the LED is used to indicate the button input Fig 18 Parameter window Control by i...

Page 43: ...object in X will be shown in Fig 19 the LED is used to indicate the input of the communication object Fig 19 Parameter window Indicate object X Parameter LED on time This parameter defines the indicative time of LED when there is input of communication object which means the switch on time Options 100ms 200ms 60s ...

Page 44: ...ect out X will be shown in Fig 20 the LED is used to indicate the output of the communication object Fig 20 Parameter window Indicate object out X Parameter LED on time This parameter defines the indicative time of LED when there is output of communication object which means the switch on time Options 100ms 200ms 60s ...

Page 45: ...t X will be shown in Fig 21 the LED is used to indicate the input and output of the communication object Fig 21 Parameter window Indicate object in and out X Parameter LED on time This parameter defines the indicative time of LED when there is input or output of communication object which means the switch on time Options 100ms 200ms 60s ...

Page 46: ...ction this communication object will be active to disable enable the channel function The communication object will disable this function if receive a telegram with logic value 0 while it will enable the channel function if receive a telegram 1 The control telegram sent by all objects are ineffectiveness when the channel function disable The channel function default to enable when the bus voltage ...

Page 47: ... will not list in Fig 6 3 This different data types communication object have the same operation that are transmit the input object value which the range of transmit object value are different It is possible to distinguish a long short operation or not the two objects enable when distinguished Fig 6 3 Communication object Value Forced output No Function Object name Data type Flags DPT 1 CH X Value...

Page 48: ...ange is depending on the data type if the data type of the communication object is different the import ability range of the object value is different The data type depends on parameter Reaction on long operation Form 3 Communication object Value Forced output 6 4 Communication object Scene control The communication object Scene control will be shown in Fig 6 4 it is including the actuator group a...

Page 49: ...t have the function modify W and update U Assuming an 8 bit command binary coding as FXNNNNNN F invocate the scene with 0 save the scene with 1 X 0 NNNNNN scene number 0 63 6 CH X Store scene Store scene X 1bit C W T 1 002 boolean This parameter trigger the scene storage or indicate the accomplish of the scene by bus decided by the mode of the scene storage The detail storage process will be descr...

Page 50: ...01 counter pulses signed This communication object is used to transmit the current counting value of the standard counter and it can modify the counting value simultaneously Different data type makes the different counting range it is defines by parameter Date width of counter 2 CH X Differential Counter Differential Counter 1byte X 1byte 2byte 4byte 1byte 2byte 4byte C W T 5 010 counter pulses 0 ...

Page 51: ...e communication object Multiple Operation will be shown in Fig 6 7 The value of the designate operation object will be modify if detect multiple operation in period Fig 6 7 Communication object Multiple operation No Function Object name Data type Flags DPT 1 4 CH X 1 fold 1 4 Output 1 fold X 1 4 1Bit C T 1 001 switch The number of the communication object maximum 4 is set by parameter Max number o...

Page 52: ...lower moving if the object receive a logic value 1 and negate it if receive 0 Form 8 Communication object Shutter control 6 9 Communication object LED X flashing The communication object LED X Flashing will be shown in Fig 6 9 Fig 6 9 Communication object LED X Flashing No Function Object name Data type Flags DPT 28 LED X Flashing LED Flashing X 1Bit C W 1 001 switch It is used to control the LED ...

Page 53: ...op LED if receive 0 or 1 29 LED X Permanent on LED permanent on X 1Bit C W 1 001 switch It is used to open LED for a long period and its priority is higher than the communication object LED switch X It will open LED if receive telegram 1 negate priority and the LED resume the foregoing operation if receive 0 30 LED X Send its status Send its status X 1Bit C T 1 001 switch It is visible if Send sta...

Reviews: