8 European authorized representative

9 Symbol instruction 

Follow Instructions 

for Use

CE marked product

  Date of manufacture

  

Manufacturer

Type B applied part 

 

Recovery

 

Handle with care

Keep dry

Ordinary device

Anti-drip device

Used indoor only

Purging mode

Alternating current

Foot switch

Protective earthing

Sterilization under high 

temperature

Power Switch

30V DC

Direct current

Cooling water or 

flushing water

Appliance compliance WEEE directive

Storage condition, humidity limit: 10% ~ 93%

Storage condition, air pressure limit: 70kPa ~ 106kPa

Storage condition, temperature limit: -20°C

 ~ +

55°C

Summary of Contents for AP-A

Page 1: ......

Page 2: ... Troubleshooting 8 4 Cleaning Disinfection and Sterilization 9 5 Maintenance storage and transportation 15 6 Environment protection 17 7 After service 17 8 European authorized representative 18 9 Symbol instruction 18 10 EMC Declaration of conformity 19 11 Statement 23 ...

Page 3: ...ctions it s easy to assemble and disassemble and easy to clean 3 The handpiece can be free to plug and can be sterilized in the environment of 134 C and 0 22MPa pressure 1 1 Product model AP A 1 2 Product Configuration For more information see packing list 1 3 Structure and components It mainly consists of main unit handpiece nozzle foot switch powder tank water bottle power adapter prophylaxis po...

Page 4: ... 1 7 1 Power adapter input 100 240V 50 60Hz 1 1A Model USE48 300130SPA3 1 7 2 Main unit input 30V 1 3A 1 7 3 Main unit insurance T1 6AL 250V 1 7 4 Air inlet pressure 5 5bar 7 5bar 0 55MPa 0 75MPa 1 7 5 Main unit weight 2 0kg 1 7 6 Main unit size length width height 270mm 170mm 90mm 1 8 Operation environment 1 8 1 Environment temperature 5 C 40 C 1 8 2 Relative humidity 30 80 1 8 3 Atmospheric pres...

Page 5: ...ew of main unit 2 1 3 Touch panel Fig 3 Touch panel After power on the button will be blue If there is no air connection or the air pressure is insufficient the blue light flashes 2 1 4 Schematic diagram of handpiece ...

Page 6: ...g and press the power switch to shut down Warning 1 To avoid the risk of electric shock this equipment must only be connected to a supply mains with protective earth Warning 2 When the power adapter is connected to the network power supply do not place or install the product in a place where it is difficult to cut off the network power supply Warning 3 Unauthorized modification of this equipment i...

Page 7: ...ank When the powder in the powder tank is used up please click the Purging Mode button twice to remove the compressed air in the powder tank and then add powder into powder tank It is unallowed to add powder when in use Tip 1 Do not exceed the maximum MAX mark Tip 2 The supragingival powder can only be used in the supragingival powder tank The subgingival powder can only be used in the subgingival...

Page 8: ...urface during treatment Fig 5 schematic diagram of grit blasting on gum 2 3 5 Subgingival airpolishing 2 3 5 1 When the depth of the patient s periodontal pocket exceeds 4mm subgingival airpolishing is recommended 2 3 5 2 Install the nozzle before use take out the nozzle assemble the nozzle to the end of the subgingival handpiece Rotate the nozzle nut to the head handpiece first and then lock the ...

Page 9: ... 2 4 Maintenance 2 4 1 Airpolishing handpiece 2 4 1 1 Remove the air polishing handpiece loosen the handpiece head and pull out the handpiece head For subgingival handpiece the nozzle needs to be removed in advance as shown in fig 7 2 4 1 2 Align the handpiece head with a three way syringe and blow away the residual powder in the handpiece 2 4 1 3 Blow the front and rear ends of the handpiece with...

Page 10: ... pour out the powder remaining in the powder tank after use 2 4 2 2 Use a three way syringe to clean the powder remaining in the powder tank and blow away the powder in the thread of the powder and powder tank lid 2 4 3 Daily maintenance Before and after using airpolishing system please click the purge button on the main unit 3 Troubleshooting Failure Possible cause Solutions After power off there...

Page 11: ...ter Solenoid valve failure Contact local distributors or manufacturer Solenoid Valve blocked due to impurities Open the main unit dredge solenoid valve or contact local distributors or manufacturer There is no air and water spray Abnormal foot switch connection Reconnect foot switch Foot failure Repair or replace foot switch Powder tank leakage Seal ring damaged Replace seal ring Airpolishing hand...

Page 12: ...vice works for 20 30 seconds at maximum water volume to separately flush the Air polishing handpiece and nozzle Remove the handpieces from the device and rinse away the dirt on the surface of handpieces and their accessories with pure water or distilled water deionized water Dry the handpieces and its accessories with a clean soft cloth and place it in a clean tray Precautions 1 The water used her...

Page 13: ...ng water desalted water distilled water or deionized water for at least 5 times with duration of no less than 60 seconds for each time Check whether the cleaned parts are clean or damaged If the cleaning is not complete repeat the previous cleaning procedures The intrinsic suitability of the handpieces and its accessories for effective cleaning using the above procedure was verified by a validated...

Page 14: ...aptor and attach the handpieces to the rinsing connections of the washer disinfector so that the surface and internal water lines can be flushed during cleaning process Start the program After the program is finished remove the handpieces and its accessories from the asher disinfector inspect refer to section Inspection and Maintenance and packaging refer to chapter Packaging Dry the handpieces an...

Page 15: ...section Inspection and Maintenance and packaging refer to chapter Packaging Dry the handpieces and its accessories repeatedly if necessary refer to section Drying Verification of the fundamental suitability of the handpieces and its accessories for effective manual cleaning and disinfection was provided by a verified testing laboratory Precautions 1 The disinfectant used to configure the disinfect...

Page 16: ...al parts are broken please replace it before use But the replaced parts must be cleaned disinfected and dried 5 Do not use the machine when the machine is being cleaned disinfected sterilized 4 6 Packaging The disinfected and dried handpieces and their accessories are assembled and quickly packaged in a medical sterilization bag or special holder sterile box Precautions 1 The package used conforms...

Page 17: ...es that have not been recommended If you use the sterilization procedures that have not been recommended please adhere to related effective standards and verify the suitability and effectiveness Fractionation pre vacuum procedure a procedure for steam sterilization by repeating pre vacuum the procedure used here is steam sterilized by three pre vacuums 5 Maintenance storage and transportation 5 1 ...

Page 18: ...nd ventilated place 5 2 2 Do not mix with toxic corrosive flammable and explosive articles during storage 5 2 3 The product should be stored in an environment where the relative humidity is 10 93 the atmospheric pressure is 70kPa 106kPa and the temperature is 20 C 55 C 5 2 4 When this device is not in use for a long time it should be powered on and ventilated once a month at least five minutes eac...

Page 19: ...art exceeds the limit requirement specified in SJ T 11363 2006 Please dispose according to the local laws or consult with dealer from whom you purchased it about waste disposal 7 After service We offer one year free repair to the device according to the warranty card The repair of the device should be carried out by professional technician We are not responsible for any irretrievable damage caused...

Page 20: ...dry Ordinary device Anti drip device Used indoor only Purging mode Alternating current Foot switch Protective earthing Sterilization under high temperature Power Switch 30V DC Direct current Cooling water or flushing water Appliance compliance WEEE directive Storage condition humidity limit 10 93 Storage condition air pressure limit 70kPa 106kPa Storage condition temperature limit 20 C 55 C ...

Page 21: ...the user of the model AP A should assure that it is used in such an environment Emissions test Compliance Electromagnetic environment guidance RF emissions CISPR 11 Group 1 The model AP A RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR11 Class B The model AP A RF energy o...

Page 22: ... 2 kV Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 11 0 UT 0 5 cycle At 0 45 90 135 180 225 270 and 315 0 UT 1 cycle and 70 UT 25 30 cycles Single phase at 0 0 UT 250 300 cycle 0 UT 0 5 cycle At 0 45 90 135 180 225 270 and 315 0 UT 1 cycle and 70 UT 25 30 cycles Singl...

Page 23: ...Hz 80 AM at 1 kHz 385 MHz pulse modulation 18 Hz 27 V m 450 MHz FM 5 kHz deviation 1 kHz sine 28 V m 710 MHz 745 MHz 780 MHz pulse modulation 217 Hz 9 V m 810 MHz 870 MHz 930 MHz pulse modulation 18 Hz 28 V m 1 720 MHz 1 845 MHz 1 970 MHz pulse modulation 217 Hz 28 V m 2 450 MHz pulse modulation 217 Hz 28 V m 5 240 MHz 5 500 MHz 5 785 MHz pulse modulation 217 Hz 9 V m Portable and mobile RF commun...

Page 24: ...nt and the model The model is intended for use in electromagnetic environment in which radiated RF disturbances is controlled The customer or the user of the model can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the model is recommended below according to the maximum output power of the communi...

Page 25: ...ecker reserves the right to change the design of the device the technique fittings instruction manual and the content of the original packing list at any time without further notice The pictures are only for reference The final interpretation rights belong to Guilin Woodpecker Medical Instrument Co Ltd The appearance of the product was authorized patent and counterfeit will be sued Please refer to...