Working with Reflections
Detecting a Target
The RangeGuard Monopole System automatically detects a monopole target when it
comes into range and displays a yellow circle in the centre of the BEV.
Reflections Pane
The Reflections pane is obtained by clicking on the
Tracking
button and then on the
Reflections
tab. It displays the following controls and information:
Range & Bearing Data:
Target
- The target for the reflection matching that shown on the BEV. Clicking on the
target has the same effect as clicking on the target on the BEV
Type
- The type of reflection as follows:
•
Reflection:
A target signal has been detected and verified
•
Reject:
A target signal has been detected and rejected by the sensor
Range
- The measured distance between the target and the vessel’s reference point,
expressed in metres.
Bearing
- The bearing of the target in relation to the vessel’s centre-line, expressed in
degrees.
Visibility
- The strength of the detected signal from the target, expressed as a percentage.
Sensor Quality
- The confidence of the target range from the respective sensor,
expressed as a percentage.
Summary of Contents for RangeGuard Monopole