Failure removal
Fault
Cause
Elimination
Engine does not start
1. Empty tank
2. Dirty air filter
3. Weak ignition spark
4. „Over-swilled“ engine
1. Fill the tank up to its full capacity; check
whether the carburettor contains a fuel; check
tank de-aeration and make an opening in the
tank lid with a needle.
2. Clean the air filter.
3. Clean the spark plug or install the new
one if necessary; check the ignition cable; let
the ignition checked in a service.
4. Unscrew the spark plug, clean it and dry;
pull several times the starting string when the
spark plug is unscrewed.
Engine outages occur
1. Ignition cable is loosened.
2. Fuel piping is clogged or fuel is bad.
3. Ventilation opening in the fuel tank lid
is blocked
4. There is water or dirt in fuel piping.
5. Air filter is dirty.
1. Fit the spark plug extension firmly onto the
spark plug.
2. Clean fuel piping, use fresh fuel.
3. Replace the fuel tank lid.
4. Drain the fuel and refill clean and fresh fuel.
5. Clean the air filter.
Engine often stop at idle run
1. Ignition distance is too long, spark plug
is defective.
2. Carburettor is not adjusted precisely.
3. Dirty air filter
1. Adjust or replace the spark plug.
2. Adjust the carburettor.
3. Clean the air filter.
Drive does not work properly
1. Check the drive handle string tension.
2. Drive does not work.
1. Perform additional adjustment of drive
handle string tension if necessary.
2. Let the machine checked in a service
point.
Unusual vibrations
1. Blade is damaged or blunt.
2. Fixing screws are loosened.
1. Replace the knives.
2. Tighten the fixing screws.
Unsatisfactory result
Blunt blades
Replace the blades.
Inspection and maintenance plan
Non-compliance with the maintenance plan may result in damage to the motor!
Regular servicing period
Before any
start-up
After 1
month
After 3
months
After 6
months
After 12
months
After 24
months
5
Hours of
operation
25
Hours of
operation
50
Hours of
operation
100
Hours of
operation
250
Hours of
operation
Engine oil
(10W-40)
Inspection
Change
Air filter
Inspection
Change
Spark plug
Inspection
Clean
Change
Carry out the appropriate maintenance in the month specified or after being operated for the number of operating hours specified, depending on
which occurs first.
Summary of Contents for 95457
Page 6: ...2 1 3 2 4 1 2...
Page 7: ...3 5 7 8 10 9 11 6 1 2 1 2 1 2...
Page 8: ...4 1 2 2 3 4 1 2 3 1 1 2 2 2 2 M6X20 M6 2 3 2x...
Page 9: ...5 5 8 7 6 9...
Page 10: ...6 1 2 4 3 5...
Page 11: ...7 6 8 9 7 10...
Page 12: ...8 11 12 14 13 15 16 1 2 2 2 2 4x...
Page 14: ...10 MIN 5 MIN 3 4 6 Test 10W 40 MAX 0 55 ltr MAX 0 55 ltr...
Page 16: ...12 min 3 00 m S T A R T 2 3 1 SUPER SUPER PLUS SUPER E10 NORMAL NORMAL E10 3 6 ltr...
Page 17: ...13 1 2 3 S5 DCT 11 20 cm 4 5 6 MAX MIN MAX 0 4 ltr MIN S5 DCT 11 S5 DCT 11...
Page 18: ...14 1 1 2 2...
Page 20: ...16 2 1 a OFF a b b OFF STOP S T O P P...
Page 21: ...17 2a 1 2b 3...
Page 22: ...18 4 5 4a 4b 5a CLICK CLICK...
Page 23: ...19...
Page 25: ...21 0 7 0 8 mm 2 3 1 4...
Page 26: ...22 1 2 3 4 H2 O 5 6 1 2 3...
Page 28: ...24 24 1 2 3...
Page 89: ......