Throat for Oil Adding and Oil Level Inspection 

 
Transport stopper needs to be exchanged for throat for oil 
adding and correct oil level needs to be ensured before 
putting the compressor into operation. 
 

Check the oil level at every startup!!! 
 
Oil change 

 
Since arriving on the piston can chip, it is absolutely 
necessary after the first 10 hours of operation to carry out 
an oil change. We recommend that you are our 
compressor (SKU: 40056). Later, depending on the 
operation of the compressor, all 100 to 200 hours of 
operation an oil change place. In order to carry out oil 
changes, open the drain screw (13) and begin the 
process of waste oil in a suitable container. 

Observe strictly the rules for disposal of waste oil 
and dispose of it properly in a waste oil collection 
center. Unscrew the drain screw is now firmly back 
on and fill oil up to the mark on the dipstick 
In winter we recommend a lubricity oils to start 
during the cold season to help! 
 
Air-pressure switch: 

 
The compressor is equipped with an automatic air-
pressure switch that will switch the compressor off after 
reaching the upper limit of the operating pressure and 
switch it on again when air is needed. 

Starting pressure 

of 8 bar, max. pressure of 10 bar.

 

 
Inspections and Maintenance 

 
Pull the connector plug out of socket before each work on 
the machine. If you are not going to use the device for a 
longer period of time we recommend dropping a few oil 
drops at the place of air filter insertion so that walls of 
cylinders were lubricated at next compressor switching 
on. 

 

Use a damp cloth for cleaning of plastic parts. Do 
not use cleaners, solvents or sharp objects. 

 

Clean the air holes and mobile parts with a soft 
brush off the settled dust after each use. 

 

Regularly paint all metal parts with oil. 

 

After each use 

clean the air holes and mobile parts off dust. 

 
Regularly 

paint metal parts with oil (universal oil) check whether all 
screws are tightened.  

 

Regularly (once a month at least) release the 
condensed fluid from the air jet; failing to observe 
this regulation may lead to guarantee for rusting 
through expiry – apart from that, the compressor is 
maintenance-free. (The condensed fluid may be 
brown-coloured due to surface layer from the air jet) 

 
1. 

Pull the connector plug out of socket! 

2. 

At low pressure in the air jet open the bleeder 

(9)

 

(max. of 1 bar) and completely empty the condensed 
fluid (use a suitable container)  

3. 

Close the valve. 

 

 
Air filter 

Sometimes it is necessary to clean the filter bed. For that purpose 
remove the air filter cover screw and remove the foam filter. Wash 
it in warm soap water solution. Let the foam filter dry and reinsert 
it to its place. Now assemble the air filter cover again. 
 

Fuse against overheating: 

 Vérifiez régulièrement la tension de la courroie. 

 

 

If the compressor is loaded by a technical defect or possibly 
also by continuing operation, the power feed will be 
automatically interrupted by a thermo-switch. If such 
situation occurs it is advisable to disconnect the compressor 
from the mains and let it cooled down for approx. 5 minutes. 
If the compressor does not start after certain period of 
operation, let it cooled down for additional 3 minutes. 

 

V-belt 

 Check 

regularly

 the V-belt tension.  

 
If the V-belt needs to be tightened, proceed as follows: 

 

Unscrew the 4 engine screws.  

 

Tighten the V-belt by pushing the engine away off the unit. 

 

When the V-belt is tightened, the engine screws must be 
tightened again.  

 

It is necessary to make sure that both pulleys match each 
other. 

 

Protection against overheating 

 
If the compressor is overloaded by e.g. long-term operation, 
current supply is automatically interrupted by the thermal 
switch. The compressor is recommended to be disconnected 
and the engine cooled down for app. 5 minutes.  
 

 

Risk of injury! The compressor may automatically get 

started after cooling down (app. 5 minutes). 

 
Engine overloading protection 

 
If the engine overloading protection is activated when the 
appliance is in operation, the appliance has a defect. Please 
notify the service department of Güde or an electrical 
professional.  
 

Important instructions 
 
Appliance depressurising does not work 

The depressurising process is disabled by unplugging the 
appliance or decreasing the voltage in the system when the 
compressor is switched on.

 

 
Depressurising process reactivation: 

Switch the compressor off by the ON/OFF button. The appliance 
is depressurised. Connect the plug and switch the compressor 
on by the ON/OFF button. 
 

WARNING: 

There may be relatively high values of the build-up current at 
compressors with a capacity exceeding 2.0 kW. These values 
may activate the protective power switches in your household 
installation system. 

It is no defect! 

In such a case, please 

contact an electrical professional who will provide appropriate 
protection.

 

 
 
 
 
 
 
 

14

Summary of Contents for 380/10/50 KR 15 TLG

Page 1: ...SSOR EMSEMBLE Ce tina CZ 24 Origin ln n vod k obsluze KOMPRESOR NASTAVIT Sloven ina SK 30 Origin lny n vod na obsluhu KOMPRESOR NASTAVIT Nederlands NL 37 Originele gebruiksaanwijzing COMPRESSOR SET It...

Page 2: ...2 1 3 13 3 7 13 15 6 12 9 10 4 5 2 4 1 3 230 V 50 Hz 44 kg 2 2 kW 3PS S3 50 ca 340 l min ca 240 l min 10 bar 50 l LWA 95 dB 12 11 14 8...

Page 3: ...mmer Artikelnummer Baujahr Tel 49 0 79 04 700 360 Fax 49 0 79 04 700 51999 E Mail support ts guede com Kennzeichnung Produktsicherheit Produkt ist mit den einschl gigen Normen der Europ ischen Gemeins...

Page 4: ...urch Fremdk rper Nichtbeachtung der Gebrauchs und Aufbauanleitung und normaler Verschlei sind ebenfalls von der Gew hrleistung ausgeschlossen Allgemeine Sicherheitshinweise Die Bedienungsanleitung mus...

Page 5: ...und Geh rschutz tragen Immer Schutzbrillen oder einen entsprechenden Augenschutz und einen Geh rschutz tragen Den Druckluftstrahl nie auf den eigenen K rper oder auf andere Personen oder Tiere richte...

Page 6: ...lfe an Bewahren Sie den Verletzten vor weiteren Sch digungen und stellen Sie diesen ruhig F r einen eventuell eintretenden Unfall sollte immer ein Verbandskasten nach DIN 13164 am Arbeitsplatz griffbe...

Page 7: ...hlie lich von geschultem Fachpersonal durchf hren Schalten Sie den Kompressor niemals ber den Netzstecker aus da sonst keine Entlastung des Aggregats erfolgt Ohne Entlastung kann der Elektromotor durc...

Page 8: ...ufstr me auftreten Diese k nnen die Leitungsschutzschalter Ihrer Hausinstallation ausl sen Dies ist kein Defekt Bitte nehmen Sie in einem solchen Fall Kontakt mit einer Elektrofachkraft auf um eine ge...

Page 9: ...nterspannung vor G de Service verst ndigen J Kompressoraggregat ist berhitzt und der Kompressor schaltet ab Umgebungstemperatur 35 C G de Service verst ndigen R ckschlagventil verklebt Reinigen R cksc...

Page 10: ...Community Prohibitions Pulling on the cord prohibited Not to be used when raining Compressor does not take into operation without protective cover Druck nicht ber das Sicherheitsventil ablassen Warnin...

Page 11: ...ighting Do not expose electric tools to rain or high air humidity Do not switch the electric tools on in environments with flammable liquids or inflammable gases Do not allow unauthorised persons to g...

Page 12: ...d with appropriate marking only Attention It is necessary to use a cable with sufficient cross section min of 1 5 mm2 at cables longer than 10 m there may be starting problems at unfavourable temperat...

Page 13: ...r s supervision Training Appropriate training is only needed for device use No special training is necessary Transportation and Storage If the device is stored for a longer period of time it needs to...

Page 14: ...ir jet open the bleeder 9 max of 1 bar and completely empty the condensed fluid use a suitable container 3 Close the valve Air filter Sometimes it is necessary to clean the filter bed For that purpose...

Page 15: ...ean or replace the relief valve Insert of the non return valve is leaky or faulty Clean or replace the insert of the non return valve E After switch off pressure is reached the relief valve under the...

Page 16: ...y Oil level check Daily or more precisely before every putting into operation Oil replacement 1 replacement of mineral oil of synthetic oil after 50 hours of operation once a year every two years Fill...

Page 17: ...uit r pond aux normes correspondantes de la CE Interdictions Interdit de tirer sur le c ble Ne pas utiliser sous la pluie Le compresseur ne prend pas en op ration sans couvercle de protection Pression...

Page 18: ...ordre Le d sordre sur le lieu de travail et l tabli augmente des risques d accidents et de blessures Prenez en consid ration les conditions atmosph riques N utilisez pas les outils et les appareils le...

Page 19: ...e courant lectrique et rangez le dans un endroit sec et prot g des influences atmosph riques Tenez le hors de port e des enfants Tenue de travail Ne portez pas de v tements larges ou bijoux pouvant s...

Page 20: ...gers avec air comprim dans le modelage traitement des murs par a rographe gonflage des pneus etc Dangers r siduels et mesures de protection Contact lectrique direct C ble ou fiche d fectueux peut pro...

Page 21: ...eure et sa remise en marche automatique en cas de besoin en air La pression d enclenchement est de 8 bars la pression maximale de 10 bars R VISIONS ET ENTRETIEN Avant toute intervention sur l appareil...

Page 22: ...filtre d aspiration La consommation d air de l outil pneumatique est trop lev e Contr lez la consommation d air de l outil pneumatique contactez un vendeur agr Fuite sur le compresseur Localisez la f...

Page 23: ...e l huile ne soit compl t e Humidit d air lev e Changezl huile Le compresseur est surcharg Informez en le service G de Le compresseur est d fectueux Informez en le service G de Compresseur manque de t...

Page 24: ...ov d p slu n m norm m Evropsk ho spole enstv Z kazy Ta en m za kabel zak z no Nepou vejte za de t Kompresoru nebere v provozu bez ochrann ho krytu Tlak nen propustit na pojistn ventil V straha V strah...

Page 25: ...ick n ad nevystavujte de ti ani vysok vlhkosti vzduchu Elektrick p stroje nezap nejte v prost ed s ho lav mi kapalinami nebo plyny Ke stroji nepou t jte ciz osoby N v t vn ky a div ky p edev m d ti a...

Page 26: ...ze prodlu ovac ch kabel kter jsou ur eny pro venkovn pou it a maj p slu n ozna en Pozor Je nutn pou vat kabel o dostate n m pr ezu min 1 5 mm 2 u kabel del ch ne 10 m m e p i nep zniv ch teplot ch doj...

Page 27: ...a en zru nosti pod dozorem instruktora kolen K pou v n p stroje je pot ebn pouze p slu n instrukt Speci ln kolen nen nutn P eprava a ulo en V p pad ulo en p stroje na del dobu je nutno jej d kladn vy...

Page 28: ...byste m li vy istit vlo ku filtru P nov filtr vyjm te Lze jej vy istit tepl m m dlov m roztokem P nov filtr vysu te a op t jej namontujte Kl nov emen Pravideln kontrolujte nap t kl nov ho emenu Pokud...

Page 29: ...de G Pojistn ventil odfukuje Pojistn ventil je vadn Pojistn ventil vym te nebo vyhledejte servis G de P vodn vzduch nen dosta uj c Zajist te aby byl zaru en dostate n p vod i odvod vzduchu minim ln v...

Page 30: ...zodpoved pr slu n m norm m Eur pskeho spolo enstva Z kazy ahan m za k bel zak zan Nepou vajte za da a Kompresora neberie v prev dzke bez ochrann ho krytu Tlak nie je prepusti na poistn ventil V straha...

Page 31: ...e da u ani vysokej vlhkosti vzduchu Elektrick pr stroje nezap najte v prostred s hor av mi kvapalinami alebo plynmi K stroju nep ajte cudzie osoby N v tevn kov a div kov predov etk m deti a zdravotne...

Page 32: ...1 5 mm 2 pri k bloch dlh ch ne 10 m m e pri nepriazniv ch teplot ch d js k probl mom pri tartovan Pozornos Pracujte oh aduplne a pou vajte zdrav rozum Kompresor nepou vajte ak ste unaven ak ste pod v...

Page 33: ...r stroja je potrebn iba pr slu n in trukt peci lne kolenie nie je nutn Preprava a ulo enie V pr pade ulo enia pr stroja na dlh as je nutn ho d kladne vy isti a ulo i ho tak aby nebol pr stupn nepovola...

Page 34: ...emenice vz jomne l covali Ochrana proti prehriatiu Ak by do lo k pre a eniu kompresora napr dlhodobou prev dzkou d jde p soben m tepeln ho sp na a k automatick mu preru eniu pr vodu pr du Odpor ame od...

Page 35: ...ustite F Kompresor sa asto zap na Kompresor je pre a en Tlak vo vzdu n ku je vy ne nastaven vyp nac tlak Tlakov sp na nechajte novo nastavi vymeni opr vnenou osobou servis G de G Poistn ventil odfukuj...

Page 36: ...o ky Ro ne Kontrola stavu oleja Denne resp pred ka d m uveden m do prev dzky V mena oleja 1 v mena miner lneho oleja syntetick ho oleja po 50 prev dzkov ch hodin ch 1 ro ne ka d dva roky Naplnenie dop...

Page 37: ...Trekken op het snoer verboden Niet bij regen gebruiken Compressor houdt geen rekening met werken zonder beschermkap Druk niet aflaten van het veiligheidsventiel Waarschuwing Waarschuwing Let op Waars...

Page 38: ...aronder gewerkt wordt Gebruik geen elektrische werktuigen en apparaten in een vochtige of natte omgeving Zorg voor een goede verlichting Stel elektrische apparaten niet aan regen of een hoge luchtvoch...

Page 39: ...sor met de nominale elektrische spanning gebruiken De compressor met de spanning gebruiken zoals die op het typeplaatje is aangegeven Indien de compressor met een spanning gebruikt wordt die hoger dan...

Page 40: ...eerde lucht verlagen Montage rste ingebruikneming Indien de compressor zonder wielen wordt geleverd monteer deze dan zoals in afb 2 is aangegeven met een schroefsleutel De volgorde van de schroeven mo...

Page 41: ...chtfilter Van tijd tot tijd moet het luchtfilterinzetstuk schoongemaakt worden Neem het schuimstoffilter uit Voor het schoonmaken kan een warme zeepoplossing gebruikt worden Droog het schuimstoffilter...

Page 42: ...ngen Erg veel condens in de drukketel Condens aftappen F Compressor schakelt vaak in Compressor overbelast Keteldruk is hoger dan de ingestelde uitschakeldruk Drukschakelaar door een bevoegde persoon...

Page 43: ...lagventiel en inzetstuk schoonmaken ieder jaar Oliepeil controleren dagelijks resp voor ieder gebruik Olie verversen 1 Olieverversing mineraalolie synthetische olie na 50 bedrijfsuren 1 x per jaar all...

Page 44: ...Tirando il cavo vietata Non utilizzare in pioggia Compressor non prende in funzione senza coperchio di protezione La pressione non si lascia fuori della valvola di sicurezza Avviso Avviso attenzione...

Page 45: ...icurare la buona illuminazione Non esporre gli attrezzi elettrici alla pioggia oppure alta umidit dell aria Non accendere gli apparecchi elettrici nell ambiente con i liquidi oppure gas infiammabili I...

Page 46: ...l filtro d aria indicate nel capitolo Manovra Controllare periodicamente il cavo d alimentazione Se danneggiato far ripararlo e o sostituirlo presso il Centro d Assistenza Assicurare che il compressor...

Page 47: ...smaltimento derivano dai pittogrammi applicati sulla macchina e o sull imballo La descrizione dei singoli significati riporta il capitolo Indicazioni Requisiti all operatore L operatore obbligato prim...

Page 48: ...olio Dopo ogni uso Pulire dalla polvere i fori di ventilazione e le parti mobili Periodicamente Trattare le parti metalliche dell olio olio universale Controllare tutte viti se ben serrate Periodicam...

Page 49: ...ola di sfiato non tiene Pulire sostituire la valvola di sfiato L anima della valvola di ritegno non tiene oppure difettosa Pulire oppure sostituire l anima della valvola di ritegno E Raggiunta la pres...

Page 50: ...la di ritegno e dell anima annuale Controllo livello d olio Ogni giorno prima di ogni messa in funzione Cambio dell olio 1 cambio dell olio dell olio sintetico dopo primi 50 ore d esercizio annuale og...

Page 51: ...a vezet ket tilos Tilos es ben haszn lni Kompresszor nem veszi n lk l m k d sbe v d fed s Nyom s nem hagyja el a biztons gi szelep Figyelmeztet s Figyelmeztet s vigy zz Figyelmeztet s a vesz lyes maga...

Page 52: ...s gait Villanyszersz mokat s g peket ne haszn ljon nyirkos vagy nedves k rnyezetben Biztos tsa be a megfelel vil g t st Villanyszersz mokat ne hagyjon es n vagy nedves leveg n ne kapcsolja be k nnyen...

Page 53: ...onatkoz utas t sokat melyek a Kezel s c m fejezetben tal lhat k Rendszeres id k z kben ellen rizni kell a villanyvezet k belt Ha meg van rong l dva jav ttassa meg vagy cser ltesse ki szerv z k zpontba...

Page 54: ...El gtelen megvil g t s magas biztons gi kock zattal j r A g ppel val munka k zben biztos tsa be munkahelye megfelel megvil g t s t Megsemmis t s A megsemmis t si utas t sok a g pen resp a csomagol son...

Page 55: ...nz tot Ellenkez esetben megrozsd l s ez a j t ll si jog elveszt s hez vezet M sk l nben a kompresszorhoz semmif le karbantart s nem sz ks ges A kondenz t a tart ly szin t l barn ra szinez dhet 1 H zza...

Page 56: ...szelepet Visszacsap szelep bet tje nem t m r vagy hib s Visszacsap szelep bet tj t tiszt tsa ki vagy cser lje ki E A kikapcsol si nyom s el r se ut n a tehermenets t szelepb l a nyom skapcsol alatt ny...

Page 57: ...sa vente Olaj llapot nak ellen rz se Naponta illetve minden zemel s el tt Olajcsere sv nyi olaj szintetikus olaj cser je minden 50 zem ra ut n 1x vente Minden k t vben Olaj felt lt s ut n nt se Sz ks...

Reviews: