12
GPX-SL25 Instruction Manual
rev 03.21.13
CONTROL BOARD SETTINGS
1234
ON
OBSTRUCT
SENS.
PULL/PUSH
SEQ1
SNGL/DUAL
SEQ2
LEARN
DIP switches
MIN
MAX
DIP Switches
The four DIP switches on the control board match the operator with
the type of gate on which it is mounted. For example, gates may
open right to left or left to right. Prior to packaging, the
GPX-SL25 series control board was configured for a single slide gate
that opens right to left standing on the operator side of the gate.
If your gate type matches this configuration, you DO NOT need to
adjust the DIP switches. Proceed to the Potentiometers section on
the next page.
NOTE: To change the DIP switch settings, you must turn the con-
trol box power switch OFF; move the switch; then turn the power
back ON. Use a small screwdriver to move the switches.
PULL/PUSH: Set to PULL for slide gates that open RIGHT to LEFT
[factory setting]; PUSH for slide gates that open LEFT to RIGHT.
SNGL/DUAL: Set to SNGL for a single gate leaf [factory setting];
DUAL for dual gate leaves.
1. KEEP CLEAR! Gate may move at any time.
2. Do not allow children to operate gate or
play in gate area.
3. This gate is for vehicles only. Pedestrians
must use a separate entrance.
Moving Gate Can Cause
Injury Or Death
WARNING
!
Operator
1234
ON
PULL/PUSH
SEQ1
SNGL/DUAL
SEQ2
Gate Opens Right
Dip Switch 4 Set to Push.
1. KEEP CLEAR! Gate may move at any time.
2. Do not allow children to operate gate or
play in gate area.
3. This gate is for vehicles only. Pedestrians
must use a separate entrance.
Moving Gate Can Cause
Injury Or Death
WARNING
!
Operator
1234
ON
PULL/PUSH
SEQ1
SNGL/DUAL
SEQ2
Gate Opens Left
Dip Switch 4 Set to Pull.