- 31 -
PTIS 1000
5.2.1 Operation with a CA module
In order for this function of the CA module to be possible, in the "Selecting the
input data stream" – "
INPUT
" menu (page 20) an input signal source must be
selected whose data stream contains services which can be descrambled by
the CA module you are using and your smart card. Where both scrambled
stations and unscrambled regional services are transmitted, short-term picture
loss may occur when switching between scrambled and unscrambled services.
Setting the PID monitoring
The factory default of the PID monitoring is switched on.
If particular PIDs are not descrambled the CI module is reset. Additionally
dropouts may occur if several services are descrambled. To prevent this the PID
monitoring can be switched off.
Bx 4A
PID Check
CA
on
• Use the
buttons to switch "
off
" or "
on
" the PID monitoring.
• Press the
button.
—> The "Configuring the CA module" – "
CA
" menu is activated.
Configuring the CA module
The menu varies according to which CA module you are using. For this rea-
son, please refer to the operating manual of your particular CA module. The
relevant information is shown in the display of the head-end station. This may
appear as a fixed display or as scrolling text according to display capabilities.