GSS PTIS 1000 Assembly Instructions Manual Download Page 19

 

 

- 19 - 

PTIS 1000

 

Setting the address range

 

In this menu you define the address range for the cassettes connected to the 
LAN network.

Bx 4
255.255.255. 

0

IP-MASK

 

•  Use the

 

 buttons to place the cursor under the digit of the IP address 

displayed to be set and use 

 to set the IP address wished.

 

•  Press the 

 button.

 

—>  The "Setting the address of the gateway" – "

IP-GATEWAY

" menu is acti-

vated.

 

Setting the address of the gateway

 

The IP address of a gateway (server) can be set in this menu. If no gateway is 
used you can skip this setting.

Bx 4
192.168. 

0. 

1

IP-GATEWAY

 

•  Use the

 

 buttons to place the cursor under the digit of the IP address 

displayed to be set and use 

 to set the IP address wished.

 

•  Press the 

 button.

 

—>  The "Setting the UDP port" – "

UDP-PORT

" menu is activated.

 

Setting the UDP port

 

The UDP port setting is required if the cassette needs to be reached externally 
to make the setting, such as from another input frequency. This setting is in-
tended for future functions and can be skipped for this cassette. 

Bx 4
60000

UDP-PORT

Summary of Contents for PTIS 1000

Page 1: ...0 Head End DVB T Converter to IP DVB T to SPTS CLASS KLASSE GSS Grundig SAT Systems GmbH Beuthener Strasse 43 D 90471 Nuremberg Phone 49 0 911 703 8877 Fax 49 0 911 703 9210 E mail info gss de Internet http www gss de ...

Page 2: ... the cassette 17 Selecting the cassette displaying the software version 17 Setting the Ethernet parameters 18 Setting the IP address of the cassette 18 Setting the address range 19 Setting the address of the gateway 19 Setting the UDP port 19 Selecting the input transport stream 20 Setting the input channel 21 Setting the hierarchical modulation 22 Allocating the IP addresses 23 Switching the IP a...

Page 3: ...f the service 28 Switching DVB service information on or off 28 Displaying the output data rate 29 Factory reset 29 Saving settings 30 5 2 1 Operation with a CA module 31 Setting the PID monitoring 31 Configuring the CA module 31 Descrambling services 33 6 Final procedures 34 ...

Page 4: ...ts No liability is accepted for any damage caused by faulty connections or inappropriate handling Observe the relevant standards regulations and guidelines on the installa tion and operation of antenna systems The standards IEC EN DINEN50083 and IEC EN DINEN60728 must be observed For further information please read the assembly instructions for the head end station used Test the software versions ...

Page 5: ...e following EU directives 2006 95 EC 2004 108 EC The product fulfils the guidelines and standards for CE labelling Unless otherwise noted all values are specified as typical HF input Channels C05 C12 C21 C69 Frequency range 177 5 226 5 474 858 MHz Input level 60 dBμV 80 dBμV Loop through output gain 0 dB 3 dB Return loss 8 dB Impedance 75 Ω Symbol rate acc to EN 300744 LAN interface Standard 100 B...

Page 6: ...input 17 dB 5 270 MHz Connections HF inputs 2 IEC sockets HF loop through outputs 2 IEC sockets HF output 1 IEC socket no function LAN 1 RJ 45 socket ASI input 1 BNC socket ASI output 1 BNC socket Connection strip 10 pin for supply voltages and control circuits RS 232 socket serial interface for software update Common Interface 1 several services can be descrambled ...

Page 7: ...put Principle signal path TPS Tuner A Tuner B CA Modul CA module ASI input ASI output IP address Port Service 1 212 40 50 90 1234 Service 2 212 40 50 91 1234 Service 3 212 40 50 92 1234 Service 4 212 40 50 93 1234 Service 5 212 40 50 94 1234 Service 6 212 40 50 95 1234 Service 7 212 40 50 96 1234 Service 8 212 40 50 97 1234 Service 9 212 40 50 98 1234 Service 16 212 40 50 105 1234 In the head end ...

Page 8: ... control unit must be V 41 or higher You can find the current operating software for the control unit and the cassette the software BE Flash and the current assembly instructions on the website www gss de The cassette is designed for use in the following head end stations PSU 12 PSU 8 PGT 8 and PST 19 1 2 5 Software query Control unit If necessary you can activate the indication of the software ve...

Page 9: ...board and the HF bus bar Fasten the cassette with the screws 1 0 KASSETTE KASSETTE KASSETTE KASSETTE KASSETTE KASSETTE KASSETTE KASSETTE KASSETTE KASSETTE KASSETTE KASSETTE AUSGANG max 90dBµV ACHTUNG VordemKassettenwechsel unbedingt denNetzsteckerziehen CAUTION Before changingcassettesremove mainsplug Grundig SAT Systems 1 1 3 2 EMC regulations To comply with the current EMC regulations it is nece...

Page 10: ...ion is made between the housing 19 cabinet and cable terminals 3 3 Overview of the cassette 7 8 9 0 3 2 6 5 4 1 1 HF input channel strip B 2 Status LED of the channel strip B 3 Loop through output of HF input 1 4 HF input channel strip A 5 Status LED of the channel strip A 6 Loop through output of HF input 4 7 Status LED of the LAN interface yellow LED data transfer 8 LAN socket 9 Status LED of th...

Page 11: ...use a PC or a notebook and the BE Flash software to update the software of the cassette You can find the BE Flash software and the current operating software of the cassette at the website www gss de Use a one to one cable to connect the cassette s RS 232 interface and the PC according to the wiring scheme below 9 pin D SUB socket 9 pin D SUB plug 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 If necessary u...

Page 12: ...for descrambling several services The hardware and software of this cassette have been thoroughly prepared and tested Any changes made by service providers in the data structures might impair or even prevent this function When working with the CA module please read the corresponding operat ing manual from the respective provider Insert the smart card 1 into the CA module 2 so that the chip 3 on th...

Page 13: ...erlined Use the key to select the following main menu items Setting Ethernet parameters Selecting the input Allocating the IP addresses Displaying the data rate Factory reset 4 2 Control panel The key pad on the head end station is used to scroll through the menus scrolls forward through the menus select parameters in the menus set values initiate actions selects sub menus scrolls backward through...

Page 14: ...NET Options stat DHCP A Bx 4 192 168 0 1 IP GATEWAY Bx 4 255 255 255 0 IP MASK Bx 4 192 168 0 128 IP ADDR Bx 4 60000 UDP PORT B 0 65535 Ein On Tuner A Tuner B ASI Bx 4A C30 546 0 INPUT OK Bx 4 Tuner A OK INPUT C D Kanalzug Tuner A mit CA Modul Channel strip Tuner A with Kanalzug Tuner A ohne CA Modul Kanalzug Tuner B Frequenz Feinabstimmung Frequency Fine tuning C5 C12 C21 C69 64 64 Tuner A Tuner ...

Page 15: ... DATARATE IP 1 227 40 50 60 OUT IP IP 1 7 off PKTS FEC IP 1 on UDP MODE PORT 1234 Bx 4 Das Erste IP OUT 1 on off UDP RTP 0 65535 copy off 10 9 20 19 Annex A Annex B 001 016 IP 1 TV Das Erste Bx 4 EIT TDT TXT SDT OPTIONS EIT eit TDT tdt TXT txt SDT sdt ON off all 01 IP 1 all AUDIO copy 1 7 copy auto Tuner B Bx 4A Priority high INPUT high low auto M B A Bx 4A Defaults FACTORY Bx 4A STORE FACTORY M W...

Page 16: ... ist abhängig vom verwendeten CA Modul The information displayed is dependent on the CA module used Bx 4A 01 03 Information MENU Bx 4A TV X 04 09 X entschlüsseln descrambling 0 nicht entschlüsseln no descrambling X 0 nächster Service next service Bx 4A PID Check CA on on off M D C page 14 page 15 ...

Page 17: ...witch on the head end station The display shows the software version e g V 41 The processor reads the cassettes data approx 10 seconds Ein On BE Remote please wait V 41 t 10 s Selecting the cassette displaying the software version Box 4 V 12 DVBT SPTS Box 1 Bx 1A C5 12 S3 24 TWIN SAT C07 Böx 4 C5 12 S3 24 TWIN SAT C07 Box 5 Select the cassette you want to program e g Box 4 by repeatedly pressing t...

Page 18: ... IP address of the cassette menu IP ADDR is activated Setting the IP address of the cassette If you choose to enter the Ethernet parameters manually set the IP address of the cassette in this menu If DHCP is selected the IP ADDR IP MASK and IP GATEWAY sub menus display the parameters that were assigned automati cally by a connected server If a server is not connected 0 0 0 0 appears in the corresp...

Page 19: ...ateway The IP address of a gateway server can be set in this menu If no gateway is used you can skip this setting Bx 4 192 168 0 1 IP GATEWAY Use the buttons to place the cursor under the digit of the IP address displayed to be set and use to set the IP address wished Press the button The Setting the UDP port UDP PORT menu is activated Setting the UDP port The UDP port setting is required if the c...

Page 20: ...transport streams to be processed are provided by Tuner A Tuner B and the ASI interface ASI Bx 4A Lan INPUT Press the buttons to select the signal source of the input transport stream Tuner A Tuner B ASI OK indicates that an input signal is present If there is no input signal available is displayed instead of OK Input transport stream selected ASI Press the button The menu Allocating IP addresses ...

Page 21: ...ide the input channel set the relevant input frequency is displayed If necessary use the button to activate the menu item Fine tuning 0 is displayed instead of the frequency display Bx 4A C30 0 INPUT OK 64 64 Use for fine tuning the input channel 64 64 In addition to the indicator in the display there is also a status LED which indi cates whether a transport stream is received or not LED indicator...

Page 22: ...tion conditions the receivers can receive both data streams in poorer reception conditions only the HP portion Bx 4A Priority high INPUT By pressing set to high or low not relevant in the case of standard modulation Press the button The Selecting the input transport stream INPUT menu is activated when the input signal source Tuner A without a CA module installed and Tuner B are programmed page 19 ...

Page 23: ... g Das Erste If no service is found or allocated the display shows instead of the name of the service Press the button The Switching the IP address off or on Selecting the transmission proto col Setting the port number MODE PORT menu is activated Switching the IP address off or on Selecting the transmission protocol Setting the port number In this menu you can switch off the IP address displayed a...

Page 24: ...nsmitted which makes the data transmission more robust Setting the port number Press the button to position the cursor under the port number e g 1234 Use the buttons to position the cursor under the digit of the port number displayed to be set Using the buttons set the port number wished 0 65535 Copying the settings to all IP addresses Pressing the button the settings Switching the IP address off ...

Page 25: ...ine the quantity of MPEG data packets in one IP data packet 1 7 Setting the forward error correction Press the button to position the cursor under off In position off the forward error correction FEC is switched off Using the buttons set the value of the FEC wished off 10 9 20 19 IP 1 7 10 09 PKTS FEC AnnexB Setting the transmission channel Press the button to position the cursor under Annex Use t...

Page 26: ...exclamation mark ap pears in the first line of the display beside the number of the IP output IP 1 227 40 50 60 OUT IP Allocating IP addresses to services manually Press the buttons to position the cursor under the digit of the IP ad dress to be set Using the buttons set the IP address wished Allocating IP addresses to services automatically Pressing the button the first 16 of the present services...

Page 27: ...on 001 016 The 1st of 16 services is being allocated to the IP address Das Erste Name of the service Further possible terms displayed RA Type of the service Radio For radio stations the background of the screen of the connected TV or test receiver is darkened The star means that the TV or radio station selected is encoded To enable the stations the CA module and the appropriate smart card of the s...

Page 28: ...eam from the transport stream in this menu IP 1 all AUDIO Press to select the desired sound option e g all deu German 2ch etc Press the button The Switching DVB service information on or off OPTIONS menu is activated Switching DVB service information on or off In this menu the transmission of the DVB servic EIT Event Information Table TDT Time Date Table TXT Teletext SDT Service Description Table ...

Page 29: ... menu is activated Displaying the output data rate In this menu the current output data rate is displayed Bx 4A 72956 kbps DATARATE Press the button The Factory reset FACTORY Defaults menu is activated Factory reset In this menu you can reset all settings to the factory defaults M B A Bx 4A Defaults FACTORY Bx 4A STORE FACTORY M Werkeinstellwerte aufrufen invoke factory defaults Press the button T...

Page 30: ...ned to the menu item Setting the Ethernet parameters without saving the factory defaults page 18 Saving settings Press the button The settings are saved You will be returned to the Selecting the cassette menu item page 17 By pressing the button you will be returned to the menu item Setting the Ethernet parameters ETHERNET without saving the pro grammed data page 18 ...

Page 31: ...switched on If particular PIDs are not descrambled the CI module is reset Additionally dropouts may occur if several services are descrambled To prevent this the PID monitoring can be switched off Bx 4A PID Check CA on Use the buttons to switch off or on the PID monitoring Press the button The Configuring the CA module CA menu is activated Configuring the CA module The menu varies according to whi...

Page 32: ...le is activated For the explanation of further details please use the operating instructions of the CA module used Use the buttons to activate the menu desired Press the button to activate the menu Use the buttons to select the function desired To set the CA module use the and buttons All settings are saved by pressing the button You will be returned to the Configuring the CA module CA menu item B...

Page 33: ...urrently selected service will be descrambled 04 09 The 4th of 9 services read is being displayed Name of the service Further possible terms displayed RA Radio type of service 0 The currently selected service remains unchanged Use the buttons to call up the services in sequential order which are to be decoded then use to decrypt X or not to decrypt them 0 Save changes and activate the filter Press...

Page 34: ...ttes it is necessary to tighten all cable connections cable terminals and cover screws in order to maintain compliance with current EMC regulations securely Securely tighten the cable bolted connections using an appropriate open ended spanner Mount the front cover see assembly instructions of the head end station ...

Page 35: ...Alterations reserved Technical data E O E GSS GmbH V12 28012010 Service Phone 49 0 911 703 2221 Fax 49 0 911 703 2326 Email service gss de ...