Chapter 5 Display and operation
41
power is on again.
z
EE
-
rd:
parameter reading. It means to read the data in EEPROM parameter
area into the memory. The process will be executed automatically when power is
on. At the beginning, the parameters in the memory are the same as that of
EEPROM parameter area. If the parameters are modified by user, the parameter
values in the memory will be changed. If the user is not satisfied with the modified
parameter values or the parameters are disordered, the parameter reading can be
executed to read data in EEPROM parameter area into the memory to recover the
original parameters in the state of power on.
z
EE
-
bA:
Parameter backup. (Reserved)
z
EE
-
rs
:
Restoring backup. (Reserved)
z
EE
-
dEF:
Restoring default value. It means to read all default values (factory
setting) of parameters into the memory and write them into EEPROM parameter
area that they will be used when power is on again. Perform the above operation
to restore all parameters to their factory setting if the parameters are disordered
by user that cause the system to run abnormally. Because the different servo
motor corresponds to different parameter default value of the servo unit, the model
code of the servo motor must be ensured (parameter PA01) when restoring
default parameters.
Fig. 5.6 Diagram block of parameter management
Summary of Contents for DA98B
Page 1: ...GSK DA98B AC Servo Drive Unit User Manual ...
Page 2: ......
Page 9: ...Warning Ⅴ Notes ...
Page 10: ...GSK CNC Enquipment Co Ltd Ⅵ ...
Page 12: ...GSK CNC Enquipment Co Ltd 2 ...
Page 28: ...GSK CNC Equipment Co Ltd 16 Fig 3 4 Terminals and definition of CN1 ...
Page 78: ...GSK CNC Equipment Co Ltd 66 Fig 8 3 Outline and installation dimensions for BS 300 model ...
Page 79: ...Chapter 8 Isolated transformer 67 Fig 8 4 Outline and installation dimensions for BD 80 model ...
Page 80: ...GSK CNC Equipment Co Ltd 68 Fig 8 5 Outline and installation dimensions for BD 120 model ...
Page 87: ......