GSK CNC Equipment Co., Ltd.
20
270
270
控制装置侧
PULS+
PULS-
SIGN+
SIGN-
R
R
VCC
Fig. 3.8 Single terminal drive mode of pulse volume input interface
(
1
)
It is suggested to apply differential drive mode to correctly transmit pulse volume
data;
(
2
)
AM26LS31, MC3487 or RS422 linear driver are employed in the differential drive
mode;
(
3
)
Action frequency will be reduced in single terminal drive mode. According to pulse
volume input circuit, Resistance R is determined by the max. 25V voltage of external
power and 10
~
15mA drive current of the pulse input circuit. Practical data:
VCC=24V
,
R=1.3
~
2K
;
VCC=12V
,
R=510
~
820
Ω
;
VCC=5V
,
R=82
~
120
Ω
.
(
4
)
Refer to Table
3
-
4
about pulse input form, arrowhead indicates counting curb, and
Table
3
-
5
shows pulse input time sequence and parameter. If two-phase input
form is employed, 4-fold pulse frequency is less than 500kHz.
Table
3
-
4
Pulse input pattern
Pulse instruction form
CCW
CW
Parameter setting value
Pulse string sign
PULS
SIGN
0
Instruction pulse +sign
CCW pulse string
CW pulse string
PULS
SIGN
1
CCW pulse /CCW pulse
A phase pulse string
B phase pulse string
PULS
SIGN
2
2-phase instruction
pulse
Controller side
Summary of Contents for DA98B
Page 1: ...GSK DA98B AC Servo Drive Unit User Manual ...
Page 2: ......
Page 9: ...Warning Ⅴ Notes ...
Page 10: ...GSK CNC Enquipment Co Ltd Ⅵ ...
Page 12: ...GSK CNC Enquipment Co Ltd 2 ...
Page 28: ...GSK CNC Equipment Co Ltd 16 Fig 3 4 Terminals and definition of CN1 ...
Page 78: ...GSK CNC Equipment Co Ltd 66 Fig 8 3 Outline and installation dimensions for BS 300 model ...
Page 79: ...Chapter 8 Isolated transformer 67 Fig 8 4 Outline and installation dimensions for BD 80 model ...
Page 80: ...GSK CNC Equipment Co Ltd 68 Fig 8 5 Outline and installation dimensions for BD 120 model ...
Page 87: ......