4. Roof Assembly
32
PNEG-2262
24' Diameter Gamma Roof Assembly Instructions
5. When all the roof panels within a group are in place, install the remaining 5/16" x 1" flange bolts (7)
and 5/16" flange nuts (8) along the roof ribs and tighten.
6. Field drill holes (12) into the roof panels (1) through the holes in the roof panel support clips (11) and
fasten using 5/16" x 1" flange bolts (7) and 5/16" flange nuts (8).
NOTE:
Make sure that the holes are drilled from the inside of the bin.
7. Tighten all hardware to the recommended torque specifications. See bolt torque specifications
IMPORTANT:
Failure to properly secure the roof panel to the roof panel support clip and the rafter
will constitute a modification to the product not specifically delineated in this manual
and will void the limited warranty.
Figure 4U Field Drill Holes
Ref #
Part #
Description
1
CTR-0382
Roof Panel
4
CRP-7341
Roof Rafter
7
S-10260
5/16" x 1" Flange Bolt with Sealing Washer
8
S-3611
5/16" Flange Nut
11
CRP-7344
Roof Panel Support Clip
12
Roof Panel Holes Drilled Through Roof Panel Support Clips
13
Roof Panel Holes Drilled Through Roof Rafter