IMPORTANT:
An external or circuit breaker and a disconnecting switch must be installed to interrupt
power to L1 and N/L2 electric power lines before connecting the system’s main sector input
on the panel mount power supply. It must be in close proximity to the equipment and within
easy reach of the operator. It must be marked as the disconnecting device for the equip-
ment. We recommend installing it to the left of the system or to the right of the battery
enclosure.
From the power source, follow the wiring diagram to connect the main sector to the system
main sector inputs on the panel mount power supply. We recommend using a DPST dis-
connecting switch in series with a breaker. In the case of the use of a SPST disconnecting
switch, connect SPST disconnecting switch to cut the Hot line with a Neutral circuit case.
IMPORTANT:
Before plugging the system into an electrical supply, power on your system to make sure
the backup battery is functioning correctly.
CAUTION
Disconnect supply before servicing.
WARNING
Lock the enclosure when wiring is complete or when servicing. Use the nut and bolt
included or a padlock (not included) to lock the enclosure.
1. Ensure there is no switch on the power outlet.
2. Plug the wire from the power supply into a power source (AC main sector voltage).
3. Power on the system and make sure it is receiving power from the power source only.
The system works at nominal voltage between 100Vac and 240Vac for the main sector voltage. The
working voltage range is between 90Vac and 264Vac. The system consumes a current of 2.90A at
the minimum voltage on the main sector voltage input. Size your breaker circuit and the wires accord-
ing with local and national safety codes. The recommendation current value is 5A for the breaker.
Connecting the Battery to the Main Enclosure
Connecting the battery enclosure to the main enclosure is the step that allows you to power on your
system for the first time.
Before You Begin
IMPORTANT:
The Agri-Alert 128 Touch may not power up when you plug the Battery supply the first time
without AC supply.
NOTE:
Finish your installation before connecting the battery to the battery enclosure.
IMPORTANT:
It is possible that the system doesn’t power on without AC supply when the battery is
plugged in for the first time.
What You Should Know
895-00677
Agri Alert 128 Touch
27
Summary of Contents for 890-00584
Page 14: ...NOTES 14 895 00677 Agri Alert 128 Touch...
Page 20: ...NOTES 20 895 00677 Agri Alert 128 Touch...
Page 30: ...NOTES 30 895 00677 Agri Alert 128 Touch...
Page 38: ...NOTES 38 895 00677 Agri Alert 128 Touch...
Page 44: ...NOTES 44 895 00677 Agri Alert 128 Touch...
Page 64: ...Chapter 9 Configuring a 0 5 Volt Zone Type 64 895 00677 Agri Alert 128 Touch...
Page 66: ...NOTES 66 895 00677 Agri Alert 128 Touch...
Page 82: ...NOTES 82 895 00677 Agri Alert 128 Touch...
Page 88: ...NOTES 88 895 00677 Agri Alert 128 Touch...
Page 92: ...NOTES 92 895 00677 Agri Alert 128 Touch...
Page 96: ...NOTES 96 895 00677 Agri Alert 128 Touch...
Page 100: ...NOTES 100 895 00677 Agri Alert 128 Touch...
Page 102: ...NOTES 102 895 00677 Agri Alert 128 Touch...
Page 106: ...NOTES 106 895 00677 Agri Alert 128 Touch...
Page 107: ...F Wiring Diagram with Terminals 895 00677 Agri Alert 128 Touch 107...
Page 110: ...NOTES 110 895 00677 Agri Alert 128 Touch...
Page 118: ......