CONTROLLO ZONE FZ4B
77
cod. FZ4B - 06/2011 (Rev. 00)
EN
One direct zone and one hot water tank circuit
Schematic diagram
CALDAIA
318a
a
318b
155
b
72a/139a
• Management of priority/contemporaneity with parameter FZ4B P25
• Management of Economy/Comfort only with Remote Timer Control
fi
g. 24
Electrical connections
After installation, carry out the necessary electrical connections as shown in the wiring diagram.
Then con
fi
gure the controller as described in the speci
fi
c section.
RY1
RY2
RY3
RY4
RY5
RY6
RY7
RT1
RT2
RT3
T1
T2
T3
T4
7 (L)
8 (N)
9 (L)
10 (N)
11 (L)
12 (L)
13 (L)
14 (N)
15 (L)
16 (L)
19 - 20
21 - 22
23 - 24
25 - 26
27 - 28
29 - 30
30 - 31
318a
318a
318b
318b
72a/139a
155
318a
318a
318b
318b
72a/139a
155
138
318b
318a
139a
72a
138
230Vac
50Hz
L
N
IMPIANTO
155
FZ4B
X15
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24 2526 27 28 29 3031 32 33
L_N L_N L_N L
L_N
L
L L
X01
X02
X03
X09
X10
X11
X12
X13
X14
BUSRT1 RT2 RT3 T1
T2
T3T4 BLR
fi
g. 25
Key
72a
1st zone (direct) room thermostat
a
1st zone (direct)
138
External probe
b
Hot water tank circuit
139a
1st zone (direct) Remote Timer Control
____ Necessary wiring
318a
1st zone (direct) circulating pump
- - - - Optional wiring
318b
Hot water tank circulating pump
155
Hot water tank probe
To manage the sliding temperature it is necessary to purchase the external probe accessory code 013018X0
If a hot water tank thermostat (not supplied) is used, it is necessary to purchase the accessory kit code 013017X0 (to be connected in place of the Hot water tank Probe)
Summary of Contents for FZ4B
Page 292: ......