The regulator can display the following information:
t01
S1: Solar Collector Return NTC Sensor (°C)
Only with SYSTEM 4
between 01 and 125
°C
t02
S2: Hot Water Tank NTC Sensor (°C)
between 01 and 125
°C
t03
S3: Solar Collector A PT1000 Sensor (°C)
between 01 and 180
°C
t04
S4: Solar Collector B PT1000 Sensor (°C)
Only with SYSTEM 4
between 01 and 125
°C
F05
Solar circuit
fl
ow rate (Lt_min/10)
Only with Flowmeter connected and activated
00-99 Lt_min
P06
Actual modulating circulating pump speed
(40%=Speed 1 ¸ 100%=Speed 5)
- -
Press the Up/Down buttons to scroll the list of information. To display the value just press the Enter button in
relation to the parameter. In case of damaged Sensor, the regulator displays hyphens.
Press the Enter button to return to the list of information.
Press the Info button to return to the Service Menu. Press the Info button for 10 seconds to exit the regulator
Service Menu or exiting is automatic after 15 minutes.
"Hi" - History Menu
The microprocessor can memorise the total hours with regulator fed (Ht), the last 10 faults and other information;
the History datum item H1: represents the most recent fault that occurred; the History datum item H10: represents
the least recent fault that occurred.
Ht
No. hours ECOTRONIC Tech operation (Supply)
between 0 and 9999 hours
H01
Fault code
H02
Fault code
H03
Fault code
H04
Fault code
H05
Fault code
H06
Fault code
H07
Fault code
H08
Fault code
H09
Fault code
H10
Fault code
H11
No. hours Solar Circulating Pump A operation
between 0 and 9999 hours
H12
No. hours Solar Circulating Pump B operation
between 0 and 9999 hours
H13
No. hours AUX2 output relay operation
between 0 and 9999 hours
H14
No. hours FREE CONTACT output relay operation
between 0 and 9999 hours
H15
Max. temperature S1: Solar Collector Return NTC Sensor (°C)
Only with System 4
between 01 and 125 °C
H16
Max. temperature S2: Hot Water Tank NTC Sensor (°C)
between 01 and 125 °C
H17
Max. temperature S3: Solar Collector A PT1000 Sensor (°C)
between 01 and 180 °C
H18
Max. temperature S4: Solar Collector B PT1000 Sensor (°C)
Only with System 4
between 01 and 180 °C
H19
No. litres solar circuit (litres)
Only with Flowmeter connected and activated
between 0 and 9999 litres
Summary of Contents for ECOTRONIC tech
Page 6: ...ECOTRONIC tech IT Cod 3540V010 07 2010 Rev 00 6 Dimensioni ...
Page 43: ...ECOTRONIC tech 43 Cod 3540V010 07 2010 Rev 00 ES Medidas ...
Page 81: ...ECOTRONIC tech 81 Cod 3540V010 07 2010 Rev 00 EN Dimensions ...
Page 118: ...ECOTRONIC tech Cod 3540V010 07 2010 Rev 00 118 Dimensions FR ...
Page 155: ...ECOTRONIC tech 155 Cod 3540V010 07 2010 Rev 00 NL Afmetingen ...
Page 192: ......