ECOTRONIC tech
105
Cod. 3540V010 - 07/2010 (Rev. 00)
EN
The sensor fault, understood as a short circuit or open circuit, does not cause deactivation of the Solar Circulating
Pump. The system must simply work as though the System 2 were set. On eliminating the fault, the protection
is immediately deactivated.
To signal this fault, the symbol S4 will be deactivated, whereas the Fault symbol, the symbol S4 and the backlight
will start
fl
ashing.
Fault 85 - Regulator confi guration fault
Make sure parameter P26 is set to 1.
Fault 87 - Protection for no circulation
Only with
FLOWMETER ENABLED
This fault is activated when, with the Solar Pump activated, the card does not detect
fl
ow rate in the solar circuit
for 10 consecutive minutes.
The fault causes deactivation of the Solar Pump. After checking and eliminating the fault, the protection can be
removed, activating and deactivating the Off mode.
Make sure parameter P25 is correctly set.
Sensor characteristics
The temperature sensors can be checked with a digital multimeter: disconnect the sensor from regulator and
check correspondence with the following tables.
NTC
PT 1000
T (°C)
R (
Ω
)
T (°C)
R (
Ω
)
T (°C)
R (
Ω
)
-10
54932
-10
961.5
120
1462
-5
42080
-5
980.75
125
1481.25
0
32505
0
1000
130
1500.5
5
25308
5
1019.25
135
1519.75
10
19854
10
1038.5
140
1539
15
15689
15
1057.75
145
1558.25
20
12483
20
1077
150
1577.5
25
9999
25
1096.25
155
1596.75
30
8060
30
1115.5
160
1616
35
6537
35
1134.75
165
1635.25
40
5332
40
1154
170
1654.5
45
4374
45
1173.25
175
1673.75
50
3608
50
1192.5
180
1693
55
2991
55
1211.75
185
1712.25
60
2492
60
1231
190
1731.5
65
2086
65
1250.25
195
1750.75
70
1754
70
1269.5
200
1770
75
1481
75
1288.75
80
1257
80
1308
85
1070
85
1327.25
90
915
90
1346.5
95
785
95
1365.75
100
677
100
1385
105
585
105
1404.25
110
507
110
1423.5
115
442
115
1442.75
Summary of Contents for ECOTRONIC tech
Page 6: ...ECOTRONIC tech IT Cod 3540V010 07 2010 Rev 00 6 Dimensioni ...
Page 43: ...ECOTRONIC tech 43 Cod 3540V010 07 2010 Rev 00 ES Medidas ...
Page 81: ...ECOTRONIC tech 81 Cod 3540V010 07 2010 Rev 00 EN Dimensions ...
Page 118: ...ECOTRONIC tech Cod 3540V010 07 2010 Rev 00 118 Dimensions FR ...
Page 155: ...ECOTRONIC tech 155 Cod 3540V010 07 2010 Rev 00 NL Afmetingen ...
Page 192: ......