10182 E 06 - 2005
Technical information:
MODULAR VALIDATOR XV
16
Example:
Active Inactive
Pin nº6: Service request
0
1
Service output pin
0
1
1
Æ
50 msec
Å
Input pin nº 6
0
1
0
Æ
Total service time
Å
Service output
pin
¾
Work for Service Request.
Through pin 6 the time signals are requested
one
by
one
. For this to happen it is
necessary for pin 6 to change state, that is form active (0 or 1, depending on the
configuration) to inactive for a minimum of 50 milliseconds.
It is necessary for the pin to return to inactive state for a minimum of 50
milliseconds to be able to sell the following signal.
Example:
Active Inactive
Pin nº6: Service request
0
1
Service output pin
0
1
1
Æ
50
msec
Å
Æ
50
msec
Å
Input pin nº 6
0
Æ
minimum 50
msec
Å
1
Service output pin
0
Æ
Time of first
service
Å
Æ
Time of second
service
Å