10182 E 06 - 2005
Technical information:
MODULAR VALIDATOR XV
15
¾
Working in this mode, when a coin is validated one pulse of a determined duration is
given through an assigned line. An Azkoyen sorter can be controlled using pins 3, 4 and
5. This implies the use of a different exit module PCB.
In any of the working modes described below, take into account the
following information:
When the amount introduced goes over the price of the service the validator does
not accept coins and will not accept any more until the services that are
accumulated in the validator are used up.
2.2
Timing mode
The
validator working in Timing mode gives time when the programmed price is
reached. This time is configured by the user.
This
validator
offers three working modes:
¾
Work for a continued time.
On accepting the coin, the time signal is
automatically
given
all at once
, without
varying the state of the pin until it is finished. The pin is configurable.
Pin 6 works as inhibition in accepting the coin. The inhibition is configurable to level
“0” or “1”.
¾
Work for a continued time with Service Request.
On accepting the coin, the time signal is given all at once when the user requests it
through pin 6. For this to happen it is necessary for pin 6 to change state, that is
form active (0 or 1, depending on the configuration) to inactive for a minimum of 50
milliseconds. It is necessary fir the pin to return to inactive state for a minimum of
50 milliseconds to be able to sell the following signal.