13.9. Con
fi
guring HDD Error Alarms
You can configure the HDD error alarms when the HDD status is “Uninitialized” or “Abnormal”.
Steps:
1. Enter the Exception interface: Menu> Con
fi
guration> Exceptions
2. Set the Exception Type to “HDD Error” in the dropdown list.
3. Click the checkbox(s) below to select the HDD error alarm type(s), as shown below.
The alarm type can be set to: Audible Warning, Notify Surveillance Center, Send Email and Trigger Alarm Output.
Please refer to Chapter “Setting Alarm Response Actions”.
4. When the “Trigger Alarm Output” is selected, you can also select the alarm output to be triggered from the
list below.
5. Click the “Apply" button to save the settings.
141
English