4.2 Electrical connection
Fig. 5
Position of terminals
Warning
To avoid the risk of electric shock or fire,
make sure that the power supply has been
cut off before connecting the equipment.
To avoid live voltage on the cabinet, make
sure the earth terminal is reliably
grounded.
Caution
To avoid arcing and fire, tighten all
terminals with the specified torque.
For distances (pump to inverter) exceeding
30 m, we recommend a reactor with
matching current ratings.
T
M
06
65
30
19
14
Terminal
Descrip
Ɵ
on
L1
L2
L3
These terminals are the input c
ŽŶŶĞĐƟŽŶƐ
for the power
supply.
DC-
DC+/R+
R-
DC bus terminals (DC- DC+)
and
Brake resistor terminals (R+ R-)
U/T1
V/T2
W/T3
These terminals are for motor c
ŽŶŶĞĐƟŽŶƐ͘
FILTER
AC power supply
PUMP
W/T3 V/T2
(V)
(U)
(W)
(PE)
U/T1
DC+/R+
R+
DC-
L3
L2
L1
(PE)
3
1
12
2
13
3
14
4
15
5
16
6
17
7
18
8
19
9
30
10
A
11
B
Standard I/O
Terminal
Signal
1
+10 Vref
Reference output
2
AI1+
Analogue input,
voltage or current
3
AI1-
Analogue input com-
mon
4
AI2+
Analogue input,
voltage or current
5
AI2-
Analogue input com-
mon
6
24Vout
24V aux. voltage
7
GND
I/O ground
8
DI1
Digital input 1
9
DI2
Digital input 2
10
DI3
Digital input 3
11
CM
Common for DI1-DI6
*
*
Can be isolated from ground see chap
12
24Vout
24V aux. voltage
13
GND
I/O ground
14
DI4
Digital input 4
15
DI5
Digital input 5
16
DI6
Digital input 6
17
CM
Common for DI1-DI6*
18
AO1+
Analogue output,
voltage or current
19
AO-/GND
Analogue output com-
mon
30
+24 Vin
24V auxiliary input
voltage
A
RS485
Serial bus,
ŶĞŐĂƟ
ve
B
RS485
Serial bus,
ƉŽƐŝƟ
ve
Reference
pote
ŶƟŽŵĞƚĞƌ
1...10 k
ё
Remote reference
4...20mA/0...10V
mA
100X
Terminal
Description
L1
L2
L3
These terminal are the input connections
for the power supply.
DC-
DC+/R+
R-
DC bus terminal (DC- DC+)
and
Break resistor terminals (R+ R-)
U/T1
V/T2
W/T3
These terminal are for motor connections.
Pump
Filter
AC power supply
3~
Standard I/O
Terminal
Signal
1
+10 Vref
Reference output
2
AI1+
Analogue input,
voltage or current
3
AI1-
Analogue input common
4
AI2+
Analogue input,
voltage or current
5
AI2-
Analogue input common
6
24 Vout
24 V aux. voltage
7
GND
I/O ground
8
DI1
Digital input 1
9
DI2
Digital input 2
10
DI3
Digital input 3
11
CM
Common for DI1-DI6
12
24 Vout
24 V aux. voltage
13
GND
I/O ground
14
DI4
Digital input 4
15
DI5
Digital input 5
16
DI6
Digital input 6
17
CM
Common for DI1-DI6
18
AO1+
Analogue output, voltage or current
19
AO-/GND
Analogue output common
30
+24 Vin
24 V auxiliary input voltage
A
RS485
Serial bus, negative
B
RS485
Serial bus, positive
Reference
potentiometer
1...10 k
Ω
Remote reference
4...20mA / 0...10V