6.3.2 Printing of stored results
Printing all results
Note:
To cancel the entry, press the [Esc] key.
All stored data are printed out.
Printing results of a selected time period
Note:
It is possible to cancel the entry by [Esc].
If you want to print only results of one day, determine the period
by entering the same date twice.
Printing results of a selected "Code-No" range
Note:
It is possible to cancel the entry by [Esc].
If you want to print only results of one code number,
enter the same Code-No twice (as start and end code).
If you want to print all results without code number
(Code-No is 0), enter [Shift] + [0] twice (as start and end code).
Printing results of one selected method
Note:
To cancel the entry, press the [Esc] key.
Press the [Mode] key.
Press the [Shift] and [2][0] keys.
Confirm with the
key.
This display appears.
To print out all stored test results, press the
key.
This display appears.
After printing, the photometer returns
automatically to the "Mode" menu.
Press the [Mode] key.
Press the [Shift] and [2][1] keys.
Confirm with the
key.
This display appears.
Enter the date of the first day of the required
period in the following order: year, month,
day. Example: May 14, 2009 = [Shift] +
[0][9][0][5][1][4].
Confirm with the
key.
This display appears.
Enter the date of the last day of the required
period in the following order: year, month,
day. Example: May 19, 2009 = [Shift] +
[0][9][0][5][1][9].
Confirm with the
key.
This display appears.
To print all stored results in the selected date
range, press the
key.
After printing, the photometer returns
automatically to the "Mode" menu.
Shift
0
Mode
2
<Print>
Print all data
Start:
Cancel: Esc
Test No.: xx
Shift
<Print>
1
sorted: date
from yy-mm-dd
_ _ - _ _ - _ _
Mode
2
to yy-mm-dd
_ _ - _ _ - _ _
from 2009-05-14
to 2009-05-19
Start:
cancel: Esc
Press the [Mode] key.
Press the [Shift] and [2][2] keys.
Confirm with the
key.
This display appears.
Enter the start "Code-No" (max. 6-digit),
such as [Shift] + [1].
Confirm with the
key.
This display appears.
Enter the end "Code-No" (max. 6-digit),
such as [Shift] + [1][0].
Confirm with the
key.
This display appears (example).
To print all stored results in the selected
code number range, press the
key.
After printing, the photometer returns
automatically to "Mode" menu.
Press the [Mode] key.
Press the [Shift] and [2][3] keys.
Confirm with the
key.
This display appears.
Select the required method from the
displayed list or enter the method number
directly.
Confirm with the
key.
In case of differentiated methods, select the
required kind of determination and confirm
with the
key.
This display appears (example).
To print all stored results of the selected
method, press the
key.
After printing, the photometer returns
automatically to the "Mode" menu.
Shift
<Print>
2
sorted: Code-No.
from _ _ _ _ _ _
Mode
2
to _ _ _ _ _ _
from 000001
to 000010
Start:
cancel: Esc
Shift
<Print>
3
>> 30 Alkalinity-m
40 Aluminium T
60 Ammonium T
Mode
2
<Print>
Method
30 Alkalinity-m
Start:
cancel: Esc