Filtration/Deacidification
Filter systems GENO-mat KF-Z / MS-Z / AK-Z
Deacidification systems GENO-mat TE-Z
Order no. 035 129 950-inter Edited by: nkes-mrie G:\BA-129950-INTER_035_FILTERANLAGEN_GENO-MAT.DOCX
22
Table D-4: Fill volumes
1)
GENO-mat TE-Z deacidification system
20/10 25/13 30/14 40/17 40/18 50/19 60/20
Filling volumes and consumption data
Bottom filter layer I, quartz gravel 3.0 - 5.6T
[kg]
9
15
20
20
20
30
30
Bottom filter layer I, quartz gravel 3.0 - 5.6T
[l]
6
11
14
14
14
21
21
Bottom filter layer I quartz gravel (dimension
a)
[mm] 880 1100 1130 1430 1460 1380 1620
Middle filter layer II Hydrolit CA
[kg]
20
25
70
90
120
220
320
Middle filter layer II Hydrolit CA
[l]
20
25
70
90
120
220
320
Middle filter layer II Hydrolit CA (dimension
b)
[mm]
300 620 340 590 540 460 530
Free
board,
approx.
[l]
6 24 21 32 32 64 90
1)
All indications are approximate.
Centre riser pipe,
fill with filter material
1. Fill filter tank up to 50 % with water.
2. Check whether the riser pipe is covered by a protective cap, plug
on the protective cap, if necessary. The protective cap prevents
material from entering the riser pipe.
3. Centre the filter tank in the riser pipe.
4. Fill the tank with filter material. By using the funnel supplied with
the system (refer to figure). Refer to Table D-2 for fill volumes.
Remove protective cap,
secure control valve
5. Fill up the filter tank with water.
6. Centre the riser pipe properly and exactly.
7. Clean the filter tank
’
s screw thread and the sealing surface for the
connection of the control valve from any filter material that might
be clinging to them.
8. Remove the protective cap from the riser pipe.
9. Put the control valve from above onto the riser pipe and fasten it
by turning it to the right.