1.2 Electrical installa-
tion
A shock-proof plug is adequate for the electrical connection. Howev-
er, it must comply with the specifications given in table C-1, may not
be further
than 1.20 m away from the GENO-mat filter/
deacidification systems and must carry constant voltage (do not
couple with light switch)!
2 | Preliminary Work
1. Unpack all system components.
2. Check for completeness and perfect condition.
3. Place the filter tank at the designated location.
Note:
Filter/deacidification systems must be filled on site.
4. Unscrew control valve from pressure cylinder.
5. Centre the nozzle jet in the pressure cylinder and close if off by
means of adhesive tape or paper wadding.
6. Fill in the filter layers according to the filter/deacidification system
type
Filter layer I Bottom
KF-Z, MS-Z, AK-Z, TE-Z
Filter layer II Middle
KF-Z, MS-Z, AK-Z, TE-Z
Filter layer III Top
KF-Z, MS-Z
Filter layer III Top
Filter layer II Middle
Filter layer I Bottom
Fig. D-1: Filling of filter layers