6.4 Connecting the Bidirectional DC/DC Box
6.4.1 Conditions for Bidirectional DC/DC Box
The MOD 3-10KTL3-XH single-phase inverter has one independent BAT input: BAT+/BAT-
connecting to the output of Bidirectional DC/DC Box.
Notice that the connectors are in paired (male and female connectors). The connectors for Bi-
directional DC/DC Box and inverters are Helios H4-R/VP-D4/MC4
Fig 6.7
6.4.2 Connecting the Bidirectional DC/DC Box
Connection of BAT input terminal
Cable
4~6mm
2
4~6mm
2
Cable
Positive
metal
terminal
Negative
metal
terminal
Positive connector
Negative connector
Fig 6.8
21
Danger to life due to lethal voltages!
Before connecting the Bidirectional DC/DC Box, ensure that the Box do
not connect any power supply. NEVER connect or disconnect the BAT
connectors under load.
Forbidden to reverse the positive and negative poles of the Bidirectional
DC/DC Box and the inverter.
Improper operation during the wiring process can cause fatal injury to
operator or unrecoverable damage to the inverter. Only qualified per-
sonnel can perform the wiring work.
DANGER
WARNING