Output (AC)
Nominal AC power(PF=0.95)
6.65KW
7.6KW
8.55KW
Max AC apparent power
7.0KVA
8.0KVA
9.0KVA
Max. AC power(PF=1)
7.0KW
8.0KW
9.0KW
Max. output current
11.7A
13.3A
15A
AC nominal voltage;
range
230V/400V
184~275V
230V/400V
184~275V
230V/400V
184~275V
AC grid frequency;
range
50/60Hz
44-55Hz/54-65Hz
50/60Hz
44-55Hz/54-65Hz
50/60Hz
44-55Hz/54-65Hz
Power factor
0.8leading -
0.8laging
0.8leading -
0.8laging
0.8leading -
0.8laging
THDi@Full load
<3%
<3%
<3%
AC grid connection type
3/N/PE
3/N/PE
3/N/PE
Efficiency
Max efficiency
98%
98%
98%
Euro-eta
97.0%
97.2%
97.5%
MPPT efficiency
99.5%
99.5%
99.5%
Protection devices
DC reverse polarity protection
yes
yes
yes
DC switch for each MPPT
yes
yes
yes
Output over current protection
yes
yes
yes
Output AC overvoltage
Protection - Varistor
yes
yes
yes
Ground fault monitoring
yes
yes
yes
Grid monitoring
yes
yes
yes
Integrated all-pole sensitive
leakage current monitoring unit
yes
yes
yes
General Data
Dimensions(W/H/D)
490/740/235 mm
19.3/29.1/9.3inch
490/740/235 mm
19.3/29.1/9.3inch
490/740/235 mm
19.3/29.1/9.3 inch
Weight
41kg/90.4lb
41kg/90.4lb
41kg/90.4lb
Operating
temperature range
–
25 °C ... +60 °C
(–
13 °F ... +140 °F)
With derating above
45 °C(113 °F)
–
25 °C ... +60 °C
(–
13 °F ... +140 °F)
With derating above
45 °C(113 °F)
–
25 °C ... +60 °C
(–
13 °F ... +140 °F)
With derating above
45 °C(113 °F)
Noise emission (typical)
≤
55 dB(A)
≤
55 dB(A)
≤
55 dB(A)
71
72