Hint: Data units in mm
Steps:
5.3.2 Mounting Inverter
WARNING
Falling equipment can cause serious or even fatal injury, never
mount the inverter on the bracket unless you are sure that the
mounting frame is really firmly mounted on the wall after carefully
checking.
After the bracket is firmly mounted on the wall, then mount the inverter on the
bracket.
Rise up the Growatt UE a little higher than the bracket. Considering the weight of
Growatt UE, you need to hang on the inverter. During the process please maintain
the balance of the Growatt UE.
Hang the inverter on the bracket through the match hooks on bracket and the
back of the inverter.
Installed one M6*10 screw at each side of inverter to reliable fixed it on the wall.
Please reference in Fig 5.5(b).
Connection of a second protective conductor. Please reference in Fig5.6.
Recommend awning installation, the purpose is to extend the inverter service life
and reduce the power derating of the inverter. The dimension of the awning refer
to Fig5.8.
Drill holes for screws while use the mounting frame as template.6 holes for
Growatt 7000-12000UE and 8 for Growatt 18000/20000UE.
Fix the mounting frame on the wall as the figures shown below, combine as the
screws as the Items Fig 4.1 shows (items D)
Fig 5.5
Fig 5.4
17
18
a)
b)