6.4 M3 LCD Display
6.4.1 Graphic display
Position
Detail
A
Text line for displaying an event
B
Input voltage and current of MPPTA
C
Input voltage and current of MPPTB
D
PV array A and B, Light when the array voltage is above
the start voltage(300Vdc)
E
Current power
F
Daily energy
G
Total energy generated since the inverter was installed
H
Light when the array voltage is above the start voltage(300Vdc)
I
Lighted when “H” is lighted and feed-in
Output phase of the line conductor, switch every 5 seconds.
J
Output voltage /current /frequency of the line conductor
K
Graphical display of the inverter energy/power
L
M
RS232 communication
RS485 communication
External wireless communication
Internal wireless communication
6.4.2 Graph
The graph shows recent 16 hours of power
generation and the maximum value power of the 16
values.
The graph shows recent 7 days of power generation
and the maximum value power of the 7 values.
The graph shows recent 12 months of power
generation and the maximum value power of the 12
values.
The graph shows recent 16 years of power
generation and the maximum value power of the 16
values.
43
44
The inverter energy and/or power is shown as a graph on the display. The lower right-
hand bar of the graph represents the current unit of time: Day/h, Week/day,
Month/M, Year/Y. The top bar of the graph represents the maximum value of the
graph values. The daily graph is displayed by default. You can trip the enclosure lid
three times to switch the current unit of time and the generation information.