53
Models
Revision 02-2000
Toucan 1010
5.20 Overload detection setting
Check :
1- Place a 200 kg load evenly distributed on the
platform floor.
2- Position the Ground controls/Platform controls
selector switch to "Platform controls". Ensure
the lower emergency stop is not activated.
3- Apply a slight pressure F1 on the platform.
ç
An acoustic alarm sounds.
ç
The corresponding LED alarm lights up.
ç
Every function is disabled from the platform
controls.
4- Position the "Ground controls"/"Platform
controls" selector switch to "Ground controls".
ç
An acoustic alarm sounds.
ç
Every function is disabled from the ground
controls.
5- Apply a slight traction force F2 on the platform.
ç
The acoustic alarm stops.
Setting :
1- Place a 200 kg load evenly distributed on the
platform floor.
2- Loosen the locknut of the setting screw.
3- Loosen the setting screw until the sensor is
activated and the acoustic alarm sounds.
4- Apply a slight traction force F2 on the platform.
The acoustic alarm should stop. If the acoustic
alarm does not stop, tighten slightly the setting
screw.
5- When the correct setting has been found,
tighten the locknut.
6- Follow steps 3 and 4 of the checking procedure
to verify the setting is correct.
Platform floor
Lock nut
Setting screw
Overload sensor
Platform
support
200 kg
F1
F2
MAINTENANCE
5
5
Summary of Contents for toucan 1010
Page 1: ...SERVICE MANUAL Revision 02 2000 MA 0235 01 English Toucan 1010 I...
Page 2: ......
Page 3: ...3 Models Revision 02 2000 Toucan 1010 MA0235 01 Models Toucan1010 _____ Toucan1010 I _____...
Page 8: ......
Page 18: ......
Page 20: ......
Page 26: ......
Page 38: ......
Page 40: ......
Page 64: ......
Page 68: ......
Page 69: ...69 Models Revision 02 2000 Toucan 1010 LUBRICATION 7 7 1 Lubrication points TABLE OF CONTENTS...
Page 70: ......