LDM 64.1 Technical Manual rev. 1.30 - February 2020
Page 48 of 50
Index
Sub-
Index
Name
Type Attri-
but
Default Value
Meaning
0x2300 0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08
0x09
0x0A
0x0B
0x0C
0x0D
0x0E
0x0F
0x10
0x11
0x12
0x13
0x14
0x15
Number of entries.
Absolute gain
Absolute zero
Calibrate enable
Calibrate gain
Dummy
Dummy
Calibrate max 1
Calibrate min
Dummy
Calibrate zero
Decimal point
Display step size
Multi Range
Calibrate max 2
Calibrate max 3
Initial zero range
Zero Range
Tare mode
Non volatile tare
Non volatile zero
Firmware type
UI8
I32
I32
I32
I32
I32
I32
I32
I32
I32
I32
I32
I32
I32
I32
I32
I32
I32
I32
I32
I32
I32
ro
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
0x15
20000
0
-
20000
0
0
999999
-999999
0
0
3
1
0
0
0
0
0
0
0
0
0
Number of calibration parameters.
Absolute gain calibrate (TAC protected)
– AG command.
Absolute zero calibrate (TAC protected)
– AZ command.
Calibrate enable (enables TAC when the TAC is written)
– CE command.
Calibrate gain (TAC protected)
– CG command.
Not used.
Not used.
Calibrate max 1 (TAC protected)
– CM1 command.
Calibrate min (TAC protected)
– CI command.
Not used.
Calibrate zero (TAC protected)
– CZ command.
Decimal point (TAC protected)
– DP command.
Display step size (TAC protect)
– DS command.
Multi range / multi interval selection (TAC protected)
– MR command.
Calibrate max 2 (TAC protected)
– CM2 command.
Calibrate max 3 (TAC protected)
– CM3 command.
Initial zero range (TAC protected)
– ZI command.
Zero range (TAC protected)
– ZR command.
Tare mode (TAC protected)
– TM command.
Non volatile / volatile tare select (TAC protected)
– TN command.
Non volatile / volatile zero select (TAC protected)
– ZN command.
Firmware type (TAC protected)
– FT command.
0x2400 0x00
0x01
Number of entries.
Get Dose Info
UI8
I32
ro
ro
0x01
-
Number of entries.
Dose Status Info
– DI command.
0x2500 0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08
0x09
0x0A
0x0B
Number of entries.
Trigger Level
Trigger Egde
ReTrigWindow
ReTrigTime
HoldTime
TareWindow
TareTime
ReTrigStop
Dummy
Dummy
Δ Time
UI8
I32
I32
I32
I32
I32
I32
I32
I32
I32
I32
I32
ro
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
0x0B
999999
0
65535
0
0
0
0
65535
0
0
50
Number of Check-Weigher parameters.
Trigger Level
– TL command.
Trigger Egde
– TE command.
ReTrigWindow
– RW command.
ReTrigTime
– TT command.
HoldTime
– HT command.
TareWindow
– TW command.
TareTime
– TI command.
ReTrigStop
– TS command.
Not used.
Not used.
Delta time
– DT command.