LDM 64.1 Technical Manual rev. 1.30 - February 2020
Page 45 of 50
Index
Sub-
Index
Name
Type
Attri-
but
Default Value Meaning
0x2001 0x00
0x01
0x02
0x03
0x04
0x05
0x06
Number of entries.
Gross weight.
Net weight.
Tare.
Dosed weight
Dosed tare
Average weight
I32
I32
I32
I32
I32
I32
I32
ro
ro
ro
ro
ro
ro
ro
0x06
-
-
-
-
-
-
Number of entries.
Get gross weight
– GG command.
Get net weight
– GN command.
Get tare weight
– GT command.
Get dosed weight
– GD command.
Get dosed tare weight
– DT command.
Get average weight
– GA command.
0x2004 0x00
0x01
0x02
0x03
0x04
0x05
Number of entries.
Dummy
Calibration
General set-up
Save Dosed
Set-points
UI8
UI8
UI8
UI8
UI8
UI8
ro
wo
wo
wo
wo
wo
0x05
-
-
-
-
-
Number of parameters.
Not used
Save calibration settings (TAC protected)
– CS command
Save general set-up parameters
– WP command
Save dosing setup parameters command
– SD command
Save set-point parameters
– SS command
0x2005 0x00
0x01
0x02
0x03
Number of entries.
Start command.
Stop command.
Trigger command
UI8
ro
wo
wo
wo
0x03
-
-
-
Number of entries.
Start Cycle
– SC command.
Abort Cycle
– AC command.
Trigger
– TR command
0x2006 0x00
0x01
0x02
0x03
0x04
Number of entries.
Dummy
Factory Default
Command byte 1
Command byte 2
UI8
UI8
UI8
UI8
UI8
ro
wo
wo
wo
wo
0x04
-
-
-
-
Number of entries.
Not used
Set factory default values (TAC protected)
– FD command.
See RPDO1
See RPDO2
0x2007 0x00
0x01
0x02
0x03
0x04
0x05
0x06
Number of entries.
CAN network address.
CAN speed.
Dummy.
Software reset.
Dummy.
Reduce CAN output rate
UI8
UI8
UI16
UI8
UI8
UI8
UI16
ro
rw
rw
rw
wo
rw
rw
0x06
1
500
0
-
0
1
Number of entries.
CAN address
– NS1 1 command.
CAN speed
– NS1 2 command.
Dummy.
Software reset
– SR command.
Dummy.
Reduce the output rate for slow CAN systems
– NS1 6 command.