3
GB
Safety notes
Prevent danger resulting from damaged voltage
supply cables.
If damaged, the voltage supply cable must be
replaced by the manufacturer or his customer service
department or an equally qualified person.
• Installation is only possible in frost-free rooms.
• The plug-in voltage supply is only suitable for indoor use.
• The plug-in connectors must
not
be directly or indirectly
sprayed with water when cleaning.
• Use
only genuine replacement parts and accessories
.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.
Technical data
Fitting with switched-mode power supply:
• Voltage supply:
100-240 V AC 50-60 Hz/6.75 V DC
• Power consumption:
2.4 W
Fitting with battery:
• Voltage supply:
6V lithium battery type CR-P2
• Automatic safety shut-off:
60 s
(6 - 420 s adjustable)
• Run-on time (0 - 19 s adjustable):
1 s
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape (7 - 20cm adjustable):
12cm
• Type of fitting protection:
IP 59K
Thermal disinfection possible.
Electrical test data
• Software class
A
• Contamination class
2
• Rated surge voltage
2500 V
• Temperature of ball impact test
100 °C
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
Installation
, see fold-out page I-II.
Plaster and tile the wall, excluding the area of the
structural shell protection.
Flush pipes thoroughly before and after
installation
(observe EN 806)
!
Open hot and cold water supply and check that
connections are watertight.
Adjustment
Only in conjunction with wall-mounting box 36 009
see fold-out page II.
Setting the temperature
Only in conjunction with wall-mounting box 36 009
see fold-out page II.
Operation,
see technical product information, 99.0438.xxx.
Maintenance
, see fold-out page II.
•Shut off hot and cold water supply.
•Disconnect voltage supply.
•Inspect and clean all components and replace if
necessary.
Only in conjunction with wall-mounting box 36 009:
In order to ensure long-term protection from scalding, it is
necessary to perform a safety check on the fitting at least
once a year,
1. Check that the pre-adjusted outlet temperature
is not exceeded.
2. Check if the safety shut-off is working:
- Open fitting.
- Close cold water isolating valve.
- The amount of water now escaping must be no more than
a thin trickle of water. If this is not the case, the thermostatic
cartridge (47 574) must be replaced.
Replacement parts
see fold-out page I (* = special accessories)
,
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Fault / Cause / Remedy
Fault
Cause
Remedy
Water not flowing
• Filter in solenoid valve blocked
• Solenoid valve defective
• Plug-in connector without contact
- Clean filter
- Replace solenoid valve
- Check plug-in connector
Undesired water
flow
• Sensor system detection zone set too high
for local conditions
• Automatic flushing activated
• Solenoid valve defective
- Reduce range using remote control (special
accessory, prod. no.: 36 407)
- Wait 1 - 10 minutes
- Replace solenoid valve
Flow rate too low
• Mousseur dirty
• Filter in solenoid valve dirty
• Filters in connection hose dirty
- Clean or replace mousseur
- Clean filter
- Clean or replace filters
Mixing device
incorrect (36 009)
• See “Flow rate too low”
• Limescale on mixer spindle
- Clean or replace mixer spindle