Maintenance
40
Dat
e
of i
ss
u
e : J
a
nu
a
ry 2011
Automatic Greasing System
Twin-3
EG1703P03
4.6.4
Retrieving a fault code message by signal lamp
The fault message that caused the system to malfunction can be retrieved by pushing the duty
mode push-button for at least 6 seconds (20-sec. max). Directly after releasing the push button the
signal lamp will show the fault message by flash code (does not function with switch-button on
display).
The signal lamp indicates the fault codes by flashing:
-
Dozens are shown by long pulses (0,5 seconds)
-
Units are shown by short pulses (0,15 seconds)
Examples
Code that causes a pump to shut-off
Code that do not cause a pump to shut-off
ATTENTION
Fault codes can only be retrieved when the pump communication line (pin/wire no. 6) is not
connected to an Uni- or PC-GINA and need to be disconnected for at least 50 seconds before a code
can be retrieved.
Pulse
Fault code
long, short, short, short, short
14
long, long, short
21
Fault code
Meaning
11
No pressure line-A
12
No pressure line-B
13
Pressure before cycle in line-A
14
Pressure before cycle in line-B
15
Empty grease reservoir
20
Low supply voltage or bad wiring
21
Pressure switch circuit error
22
Open load pump circuit
23
Over current pump circuit
24
Open load valve 1
25
Over current valve 1
31
Open load valve 2
32
Over current valve 2
99
An error cause, not listed in the table / Replace control unit.
Fault code
Meaning
10
Currently no errors available
51
Parameter checksum error
52
Clock battery low
53
Clock error