General
Error code / malfunction
Cause
Solution
20.
+
Unknown cause
Control unit encountered an
unknown cause due to:
a. Display connected to a Twin-2
control unit (or a Twin-3
control unit with SW version
1063 or lower). Such a control
unit does not supply
additional info on the cause
of the error like the Twin-3
pump does since SW version
1078
a. Replace control unit for one
with a SW version 1078 or
higher when the additional
error information is required.
b. An error cause that is not
listed in the table.
b. Replace control unit.
Malfunction
Cause
Solution
1.
All grease points do not
receive sufficient grease and
no malfunction reports have
been given.
a. The set greasing interval is
too long for the application.
a. Choose the “heavy duty
mode” with the switch-
button and or shorten the
interval period times in
parameter section with the
use of an Uni- or PC-GINA.
b. The interval clock does not
run (wiring).
b. Check the interval clock
command wiring and
connection (green wire no. 3 /
pump connector pin no. 3).
c. The interval clock does not
run (parameter).
c. Check with the use of an Uni-
or PC-GINA whether the
“timer activation options” are
set correctly.
2.
All grease points are over
greased.
The set greasing interval for the
application is too short.
Choose the “low duty mode”
with the switch-button and or
increase the interval period times
in parameter section with the use
of an Uni- or PC-GINA.
3.
One or more grease points
do not show grease while
the other points receive
sufficient grease.
a. Squeezed or broken
secondary grease lines.
a. Check and replace the
relevant secondary line if
necessary.
b. Metering unit with lesser
output then required.
b. Mount metering unit with
larger grease output.
c. Metering unit is defect.
c. Remove and clean the
metering unit or mount a
new one.
4.
One or more grease points
receive excessive amount of
grease while the other
points do receive the right
amount of grease.
a. Metering unit with more
output then required.
a. Mount a metering unit with
less grease output.
b. Metering unit with internal
leak.
b. Remove the metering unit
and mount a new one.