Technical data
46
Dat
e
of i
ss
u
e : J
a
nu
a
ry 2011
Automatic Greasing System
Twin-3
EG1703P03
5.3
Twin display
Figure 5.3
Dimensions of the Twin display
Regulations / EMC
Off road ISO 13766-2006
Road transport 2004/104/EC
Industrial equipment 2004/108/EC
Environment
Ambient operating temperature range:
-25…+70 °C
Storage temperature range:
-25…+70 °C
Casing humidity/dust:
IP54
Electrical
Supply operating voltage range:
9…32 VDC
Max. operating current:
220 mA
Open drain outputs max current:
250 mA
Open drain max voltage:
32 VDC
Cable length max:
5 meter
TWIN
Automati
c
G
reasin
g
S
ystem
S
WIT
C
H
18.2
32.1
4.0
29.0
23.0
23.0 70.0
11
6
.0