Automatic Greasing System
Twin-3
Maintenance
37
Da
te
of
is
sue
:
Ja
nu
ar
y 2
0
1
1
EG1703P03
11.
+
Successive pump over
current
Control unit detected a too high cur-
rent draw to pump motor and
aborted the attempted cycle, caused
by:
a. Short circuit in wiring of motor
a. Check the wiring of motor.
Replace or repair when neces-
sary.
b. Short circuit in motor.
b. Check motor on wiring faulty,
check the resistance of the
motor. Replace when necessary.
c. Drive shaft blocked
c. Check the drive shaft on block-
ing. Replace or repair when nec-
essary.
d. Extreme low working
temperature in combination
with a grease not suitable for
these conditions.
d. Replace the grease in the
reservoir and bleed the system
with a suitable grease for the
obtained working conditions.
e. The "pump motor current limit"
setting not suitable for the
extreme low working
temperature.
e. Increase the "pump motor
current limit" parameter setting
but only after checking whether
the vehicle wiring and fuse can
handle a higher setting.
12.
+
Successive valve-1
open loads
Control unit detected a too low
current draw to first coil of the
5/2-way valve in combination with
initial “system on pressure before
cycle” error, caused by:
a. Interrupted wiring of the coil
a. Check wiring. Replace or repair
when necessary.
b. Defective coil
b. Check coil on wiring faulty, check
the resistance of the coil. Replace
or repair when necessary.
13.
+
Successive valve-1
over current
Control unit detected a too high cur-
rent draw to 5/2-way valve in combi-
nation with initial “system on
pressure before cycle” error, caused
by:
a. Short circuit in wiring of the coil
a. Check wiring. Replace or repair
when necessary.
b. Defective coil
b. Check coil on wiring faulty, check
the resistance of the coil. Replace
or repair when necessary.
Error code / malfunction
Cause
Solution