Automatic Greasing System
Twin-3
Principle of operation
21
Da
te
of
is
sue
:
Ja
nu
ar
y 2
0
1
1
EG1703P03
2.6
S
ignal lamp
The signal lamp is mounted in the field of vision of the driver
and out of direct sunlight, because of the visibility of the
signals. Possible this lamp can be combined with the
operating push-button. The lamp shows the status of the
greasing system and malfunction reports by means of
flashing codes. In the table below, an overview of normal
signals is given. Malfunction signals are in the fault finding
table (see page 32).
Figure 2.15
Signal lamp
2.7
Duty mode push-button
The duty mode push-button is mounted in the cabin of vehicles
that have to operate under very various circumstances (e.g.
earth moving machinery). The button is combined with the
signal lamp. The driver can adjust the greasing intensity
(greasing frequency), depending on the circumstances in which
the vehicle or machine is used. The operating mode of the
greasing system can be adjusted for light, medium or heavy
duty. The push-button influences the length of the pause
phase.
It is also possible to retrieve the fault codes on the signal lamp
by using the duty mode push-button (see paragraph 4.6.4).
Figure 2.16
Mode push-button
with signal lamp
Proceed as follows to change the active duty mode:
1.
Switch ignition ON;
2.
Depress the push-button once (heavy duty), twice (medium duty) or three (light duty) times
for 1 second;
3.
The lamp will indicate the new selected interval.
Signal
Explanation
Lamp flashes (0,5-sec. on/0,5-sec. off) as
soon as the ignition has been switched
ON.
Code
Selected duty mode
4x once
Heavy
4x twice
Medium
4x three times
Light
Default this flash code is shown 4 times with 4 second
intervals (the number of flash codes can be altered with a
parameter setting).
Lamp flashes during one complete cycle
(2,0 sec. on/2,0 sec. off)
Single greasing cycle being executed.
See paragraph 3.2.
Lamp flashes continuously
(0,2 sec. on/0,2 sec. off)
Multiple greasing cycle being executed.
See paragraph 3.3.
ATTENTION
On request the lamp functionality can be inverted (parameter setting option). When activated, the
lamp operates the other way around; Lamp switched ON where normally OFF and switched OFF
where it used to be ON.
GROENEVELD
976.01