OM/SM-TDH-CE
6
1.6 Gas Supply
Incoming gas service must be of sufficient size to
supply full rate without excessive pressure drop. A
gas meter is connected to the service pipe by the
Gas Supplier. Any existing meter should be checked
by the Gas Supplier to ensure that it has capacity to
pass the required rate of gas for the kettle in addition
to any other gas equipment installed.
The appliance governor is incorporated in the gas
control valve which is situated in the control cabinet.
The control valve governor is suitable for both
natural and propane gases without any conversion.
Installation pipe work should be fitted in accordance
with IEGE/UP/2. The pipe work should not be
smaller than the gas inlet connection on the kettle,
i.e. Rp ½ (½”BSPT).
An isolating cock must be located close to the
appliance to allow shut off during an emergency or
servicing. The installation must be tested for gas
soundness and purged as specified in IGE/UP.
1.7
Total Gas Rate - Natural and
Propane Gas
Model
Kw
BTU/hr
TDH-20
8.2
28,000
TDH-40
14.3
48,800
Water Supply —
Not applicable to these appliances.
1.8
Injector Diameters-Natural and
Propane Gas
Injector
TDH-20
TDH-40
G20 Nat. Gas
0.94 mm
1.09 mm
No. of Orifices
8
12
G25 Nat. Gas
1.09 mm
1.19 mm
No. Of Orifices
8
12
G31 Propane
Gas
0.57 mm
0.66 mm
No. of Orifices
8
12
Pilot Orifice : NATURAL - Honeywell CAR 24;
PROPANE -Honeywell BBR 10
1.9 Gas Pressure Adjustment
A pressure test point is fitted on the burner manifold
and on the gas control valve.
TDH-20
TDH-40
G20, G25
NATURAL
GAS
mbar
8.75
8.75
in. w.c.
3.5
3.5
G31
PROPANE
GAS
mbar
25
25
in. w.c.
10
10
NOTE: With reference to the gas rate, pressure
adjustments and conversions, this appliance is
approved for use with the following gases:
a) G20 natural gas may be supplied to the
appliance in Austria, Belgium, Denmark,
Finland, France, Germany, Greece, Iceland,
Ireland, Italy, Luxembourg, Norway, Portugal,
Spain, Sweden, Switzerland and the United
Kingdom.
b) G25 natural gas may be supplied to the
appliance in Belgium, France and the
Netherlands.
c) G31 propane gas may be supplied to the
appliance in France, Germany, Ireland, the
Netherlands, Portugal, Spain, Switzerland
and the United Kingdom.
Use of the appliance with non-approved gases in a
listed country, or use in other countries will void CE
certification.