background image

20 OM-DEE/4

Parts List

To order parts, contact your Authorized Service Agent. Supply the model designation, serial number, part description, part number, 
quantity, and when applicable, voltage and phase.

KEY DESCRIPTION

PART NO.

1

WATER-FILL PIPING ASSY

097007

2

SAFETY VALVE, 50 PSI

141360

3

STREET ELBOW, 1/2 NPT

004185

4

WATER LEVEL ASSY

065198

---- WATER LEVEL GLASS

008742

---- GLASS GUARD ROD

002981

---- COMPOUND PRESSURE GAUGE

084208

---- WATER LEVEL ELECTRODE

002170

5

KBA & TRUNNION, 20-GAL, NO TDO, 240V, 
CE, 50 PSI

MS102860

5

KBA & TRUNNION, 20-GAL, TDO, 240V, 
CE, 50 PSI

MS102866

5

KBA & TRUNNION, 40-GAL, NO TDO, 240V, 
CE, 50 PSI

MS100869

5

KBA & TRUNNION, 40-GAL, TDO, 240V, 
CE, 50 PSI

MS100875

5

KBA & TRUNNION, 60-GAL, NO TDO, 240V, 
CE, 50 PSI

MS102912

5

KBA & TRUNNION, 60-GAL, TDO, 240V, 
CE, 50 PSI

MS102918

6

OVERLAY, OPERATING INSTRUCTIONS

141367

7

OVERLAY, SWITCH & LAMPS

122055

8

THERMOSTAT

009730

9

TOGGLE SWITCH

122004

10

TERMINAL LUG, GROUND, 6-14 AWG

129714

11

LIMIT SWITCH

002982

12

CONTACTOR, 4-POLE

119811

13

TRANSFORMER, CE, 24V SEC 50VA

148899

14

RED LIGHT, INDICATOR, 24V

116383

14

AMBER LIGHT, INDICATOR, 24V

116384

14

GREEN LIGHT, INDICATOR, 24V

162846

15

TERMINAL BLOCK 4 POLE 85 AMP

088214

16

FUSE 3.0 AMP TYPE 3 AG

077853

17

FUSE HOLDER TYPE 3 AG

077854

18

WATER LEVEL BOARD ASSY

148323

19

PRESSURE SWITCH

096963

20

THERMOSTAT KNOB

122000

KEY DESCRIPTION

PART NO.

---- EQUIPOTENTIAL TERMINAL ASSY

122021

---- WIRING HARNESS, POWER INPUT

141365

---- WIRING HARNESS, 24V CONTROLS

EL 
WIR0607

---- WIRING HARNESS, HEATERS

EL 
WIR0608

23

BULLET FOOT

013275

23

FLANGED FOOT

096569

24

CRANK HANDLE

013617

---- 1/4" ROLL PIN

012614

---- SHAFT

013624

---- WORM GEAR

012026

---- GEAR WHEEL, 92 TOOTH

013609

---- BALL BEARING

009765

---- BEARING SLEEVE

115268

---- KEY, 3/8"

001474

---- SET SCREW

009763

---- GREASE FITTING

012100

26

DRAWOFF VALVE

009046

27

SANITARY HEX NUT

009354

28

BONNET

009024

29

VALVE STEM

009048

30

RUBBER O-RING

009034

31

HANDLE

009029

32

WING NUT, 10-24

009028

---- PRISON VALVE HANDLE, STEM, BONNET, 

HEX NUT AND LANYARD

171281

33

STAND AND HOUSING, 20-GALLON

127795

33

STAND AND HOUSING, 40- 60-GALLON

147513

 x- Item not depicted/called out in drawing

Summary of Contents for DEE-CE Series

Page 1: ...ibility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage including concealed dam age Unified Brands suggests that if you are suspicious of...

Page 2: ...Y OF THE SUPERVISOR OR EQUIVALENT TO ENSURE THAT USERS WEAR PROTECTIVE CLOTHING AND TO DRAW ATTENTION TO THE FACT THAT SOME PARTS WILL BY NECESSITY BECOME VERY HOT AND WILL CAUSE BURNS IF TOUCHED ACCI...

Page 3: ...nspection and Unpacking page 5 Installation page 6 Initial Start Up page 7 Operation page 8 9 Sequence of Operation page 10 Cleaning page11 12 Maintenance page 13 15 Troubleshooting page 16 17 Parts L...

Page 4: ...it has a tilt cut off switch low water cut off safety valve and high limit pressure switch as safety features CE units have three lights on the Control Panel The green POWER light comes on when the un...

Page 5: ...wn the model number serial number and installation date and retain this information for future reference Space for these entries is provided at the top of the Service Log at the back of this manual Ke...

Page 6: ...bserve all local and national codes and all regulations in force at the time of installation 2 Bringing the electrical service through the entrance at the rear of the support housing with one inch con...

Page 7: ...anual begin heating the water at the highest thermostat setting The heating indicator light should come on immediately and heating should continue until the water boils 7 To shut down the unit turn th...

Page 8: ...ich tilted until cranked again 2 Product may also be transferred by means of the optional draw off valve if the kettle is so equipped C Common Accessories 1 LIft Off Cover or Counterbalanced Cover As...

Page 9: ...e handling d Slowly lower product into kettle and securely hook basket to the Y frame e When removing baskets with cooked product lift straight up ensuring basket bottoms clear the kettle rim and pour...

Page 10: ...ettle is cooking below the set point the thermostat switch closes the HEAT indicator light comes on the contactors close and the heaters come on again On off cycling continues keeping the kettle at th...

Page 11: ...ve HAND TIGHTEN the nut which holds it in place 8 As part of the daily cleaning program clean soiled external and internal surfaces Remember to check the sides of the unit and control housing 9 To rem...

Page 12: ...f equipment be sanitized just before use 13 If there is difficulty removing mineral deposits or a film left by hard water or food residues clean the kettle thoroughly and then use a deliming agent in...

Page 13: ...pressure The minimum required pressure margin for this type of valve is 10 of the safety relief valve set pressure but not less than 34 5 kPa 5 psi UNDER NO CIRCUMSTANCES SHOULD THIS MARGIN BE LESS T...

Page 14: ...a If you are replacing water lost as steam use distilled water If you are replacing treated water that ran out of the jacket prepare more treated water as directed in Water Treatment Procedure b Allo...

Page 15: ...y type between the safety relief valve and the pressure vessel h WARNING During operation this valve may discharge large amounts of steam and or hot water To reduce the potential for bodily injury and...

Page 16: ...Kettle continues heating after it reaches the desired temperature User a Thermostat dial setting Authorized Service Rep Only b Thermostat circuit for short X c Thermostat operation The thermostat sho...

Page 17: ...er all the way briefly to blow the valve clean then let the lever snap back to seat the valve Authorized Service Rep Only a Safety valve for defects Replace any defective valve with an identical valve...

Page 18: ...18 OM DEE 4 Parts List...

Page 19: ...OM DEE 4 19 Parts List...

Page 20: ...WITCH 002982 12 CONTACTOR 4 POLE 119811 13 TRANSFORMER CE 24V SEC 50VA 148899 14 RED LIGHT INDICATOR 24V 116383 14 AMBER LIGHT INDICATOR 24V 116384 14 GREEN LIGHT INDICATOR 24V 162846 15 TERMINAL BLOC...

Page 21: ...OM DEE 4 21 Wiring Diagram...

Page 22: ...22 OM DEE 4 Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Page 23: ......

Page 24: ...REV C 01 15 1055 Mendell Davis Drive Jackson MS 39272 888 994 7636 601 372 3903 Fax 888 864 7636 unifiedbrands net 2015 Unified Brands All Rights Reserved Unified Brands is a wholly owned subsidiary o...