Model T1244 (Mfd. Since 10/17)
-17-
11. Insert mounting plate and router into router
table extension wing opening.
12. Make sure mounting plate and table are
aligned evenly (see
Step 11, Extension
Wing Installation on Page 15).
Figure 27. Securing mounting plate to router
base.
Mounting
Plate
Router
Bit
Mounting
Fasteners
Dust Collection
Recommended CFM at Dust Port: 100 CFM
Do not confuse this CFM recommendation with
the rating of the dust collector. To determine the
CFM at the dust port, you must consider these
variables: (1) CFM rating of the dust collector,
(2) hose type and length between the dust col-
lector and the machine, (3) number of branches
or wyes, and (4) amount of other open lines
throughout the system. Explaining how to cal-
culate these variables is beyond the scope of
this manual. Consult an expert or purchase a
good dust collection "how-to" book.
This machine creates a lot of wood chips/
dust during operation. Breathing airborne
dust on a regular basis can result in perma-
nent respiratory illness. Reduce your risk
by wearing a respirator and capturing the
dust with a dust collection system.
The Model T1244 has one 2
1
⁄
2
" dust port and an
adapter to fit a 2
1
⁄
4
" diameter shop vacuum hose.
2. Tug hose to make sure it does not come off.
Note: A tight fit is necessary for proper
performance.
If router unexpectedly moves or router bit
contacts mounting plate or fence board dur-
ing operation, serious personal injury could
result from the router bit or flying debris.
ALWAYS make sure router is firmly secured
to mounting plate before beginning any cut-
ting operations.
10. Align holes in mounting plate with threaded
holes in router base, and use fasteners
removed in
Step 5 to secure router to mount-
ing plate, as shown in
Figure 27.
Note: If original fasteners are not long enough
to properly secure router to mounting plate,
use longer fasteners purchased from your
local hardware store.
Figure 28. Dust port on fence assembly.
2
1
⁄
4
" Dust
Port Adapter
2
1
⁄
2
" Dust Port
To connect dust-collection system to item:
1. Fit 2
1
⁄
2
" dust hose over dust port (see
Figure 28) and secure in place with a hose
clamp, or connect a shop vacuum hose using
the 2
1
⁄
4
" hose adapter on dust port.