Model G0923 (Mfd. Since 05/20)
-17-
Test Run
Installing Software
Once assembly is complete, test run the machine
to ensure it is properly connected to power and
safety components are functioning correctly.
If you find an unusual problem during the test run,
immediately stop the machine, disconnect it from
power, and fix the problem BEFORE operating the
machine again. The
Troubleshooting table in the
SERVICE section of this manual can help.
To test run machine:
1. Clear all setup tools away from machine.
2. Connect machine to power supply.
3. Press switch on power adapter to turn
machine
ON.
4. Press control dial to enter main menu, then
navigate to "Auto Home." Verify that the X-,
Y-, and Z-axis motors operate smoothly and
that all axes move to machine zero.
The Test Run consists of verifying the following: 1)
The machine powers up correctly, and 2) the axis
motors run correctly and the machine properly
homes.
Injury or product damage can result from
using this machine BEFORE understanding
its controls and related safety information.
DO NOT operate, or allow others to operate,
machine until the information is understood.
To install slicer software:
1. Insert SD card into USB adapter, then insert
adapter into PC.
2. On the SD card, navigate to and open .EXE
installation file.
3. Follow directions in installation wizard.
4. When opening the software for the first time,
select Model G0923 as the default printer.
Note: We recommend backing up the installation
files by copying them from the included SD card to
a location on your computer. If installation files are
lost, they can also be downloaded from the G0923
product page at www.grizzly.com.
Grizzly Winware slicer software is included on the
SD card that comes with the Model G0923.
DO NOT start machine until all preceding
setup instructions have been performed.
Operating an improperly set up machine
may result in malfunction or unexpected
results that can lead to injury, poor work
results, or machine/property damage.