Model G0715P (Mfg. 4/11+)
-61-
Blade Tilt Stops
The table saw features stop collars that stop the
blade exactly at 45° and 90° when tilting it with
the handwheel.
The stops have been set at the
factory and should require no adjustments, unless
you notice that your cuts are not accurate.
Note: The tilt scale reads "0" when the blade is
90° to the table.
Tools Needed
Qty
90
° Square ........................................................ 1
45° Square ........................................................ 1
Hex Wrench 4mm .............................................. 1
Setting 90° Stop Collar
1. DISCONNECT SAW FROM POWER!
2. Raise the blade as high as it will go, then tilt
it toward 0° until it stops and cannot be tilted
any more.
3. Place a 90° square against the table and
blade so it contacts the blade evenly from
bottom to top, as shown in
Figure 97. Make
sure a blade tooth does not obstruct the
placement of the square.
Figure 98. Tilt indicator arrow.
—If the blade is 90° to the table, then adjust-
ments do not need to be made. Make sure
the tilt indicator arrow shown in
Figure 98
points to the 0° mark on the scale. Adjust
the position by loosening the button head
screw, moving the indicator with your fin-
gers, then tightening the screw.
Figure 97. Checking blade at 90°.
Table
90° Square
Blade
—If the blade is not 90° to the table, you will
need to adjust the 90° stop collar. Proceed
to the next step.
4. Tilt the blade away from 0° by about 5°,
so there is room for the 90° stop collar to
move.
5. Open the motor access cover, loosen the cap
screws shown in
Figure 99, then thread the
90° stop collar one turn away from the trun-
nion bracket. This will allow you to square the
blade in the next step.
Figure 99. 90° stop bolt and jam nut.
Indicator
6. Place a square against the blade, as shown
in
Figure 97, then adjust the blade until it is
perfectly square to the table.
7. Without turning the blade tilt leadscrew, fin-
ger-tighten the 90° collar against the trunnion
bracket, then tighten the two cap screws to
secure the collar position.
90° Stop Collar
Cap Screws
Trunnion
Bracket