-14-
Model G0715P (Mfg. 4/11+)
Voltage Conversion
This section shows how to convert the Model
G0715P from 220V to 110V. The plug needed for
this conversion can be purchased at any local
hardware store or electrical supply store. The cir-
cuit breaker must be purchased from Grizzly.
Items Needed
Qty
•
Phillips Head Screwdriver #2 ..................... 1
•
NEMA 5-20 Plug ......................................... 1
•
Circuit Breaker 20A (P0715P204-1) ........... 1
5. Close and secure the motor junction box.
6. Remove the start/stop switch box from the
switch mounting plate.
7. Replace the pre-installed 10 amp circuit
breaker (see
Figure 6) with a 20 amp circuit
breaker (part #P0715P204-1), then re-install
the start/stop switch.
NOTICE
This manual was current at the time of print-
ing; however, if the wiring diagram provided
on the inside cover of the motor junction
box conflicts with this manual, always use
that wiring diagram instead, as it will accu-
rately reflect any changes that may have
occurred after printing.
Converting G0715P to 110V
1. DISCONNECT SAW FROM POWER!
2. Cut off the pre-installed 6-20 plug from the
end of the power cord.
3. Open the motor junction box, then loosen the
screws indicated in
Figure 4.
Figure 4. Location of screws to be loosened.
Load
Line
KEDU HY56
20A 250V
35A 125V
Neutral
Hot
Ground
110 VAC
5-20 Plug
(As Recommended)
110V/220V
MOTOR
SWITCH
BOX
Rewired for 110V
Motor Rewired
for 110V
Motor Prewired
for 220V
Start
Capacitor
200MFD
250VAC
Run
Capacitor
60MFD
300VAC
Ground
Ground
Ground
Circuit Breaker (10A at 220V) (20A at 110V)
ON/OFF
SWITCH
Ground
Hot
Hot
6-20 PLUG
220 VAC
Rewired for 110V
Loosen
These
Screws
Center
Jumpers
4. Remove the two center jumpers (they are
stacked together), reposition them as shown
in
Figure 5, then tighten the four screws loos-
ened in
Step 2.
Figure 5. Relocated jumpers.
Load
Line
KEDU HY56
20A 250V
35A 125V
Neutral
Hot
Ground
110 VAC
5-20 Plug
(As Recommended)
110V/220V
MOTOR
SWITCH
BOX
Rewired for 110V
Motor Rewired
for 110V
Motor Prewired
for 220V
Start
Capacitor
200MFD
250VAC
Run
Capacitor
60MFD
300VAC
Ground
Ground
Ground
Circuit Breaker (10A at 220V) (20A at 110V)
ON/OFF
SWITCH
Ground
Hot
Hot
6-20 PLUG
220 VAC
Rewired for 110V
New Jumper
Location
Circuit
Breaker
Figure 6. Location of circuit breaker.
8. Install a 5-20 plug on the end of the cord,
according to the instructions and wiring dia-
grams provided by the plug manufacturer.
—If the plug manufacturer did not include
instructions, the wiring of a generic NEMA
5-20 plug is illustrated in the
Wiring sec-
tion, starting on
Page 72.