VIEWING DIAGNOSTIC CODES (CONT.)
The operator will show the code sequence number followed by the code number:
CODE SEQUENCE NUMBER
The first number shown is the most recent
code (example: "01").
The display will show the sequence of codes
that occurred starting with "01" and going up
to code "20".
TO SCROLL THROUGH SAVED CODES:
TO EXIT:
Press and release the STOP Button to exit. The display will also time out after two minutes of inactivity
TO RESET THE CODE HISTORY:
1. Press and hold the STOP button for six seconds. The display will show "Er" then "CL" alternately for six seconds.
2. Release the STOP button. The code history has now been reset and the display will show "- -" until a new code occurs.
3. Press and release the STOP button to exit.
... A SECOND LATER ...
CODE NUMBER
The second number shown after the code
sequence number is the code itself (31-99,
example" "31"). Refer to the chart on the following
page for an explanation of each code.
Press the OPEN
Button to cycle to
the most recent
code (“01”)
Press the Close
Button to cycle to
the oldest code
(up to “20”)
TROUBLESHOOTING