![GridConnect NetDirect User Manual Download Page 32](http://html.mh-extra.com/html/gridconnect/netdirect/netdirect_user-manual_2264804032.webp)
Disconnect Mode
On Mdm_Ctrl_In Drop
Set to
Yes
for the network connection to or from the serial port to
disconnect (drop) when
Modem Control In
transitions from an asserted
state to not asserted state. The default setting is
No
.
Hard Disconnect
When set to
Yes
, the TCP connection closes even if the remote site
does not acknowledge the disconnect request.
Check EOT (Ctrl-D)
Select
Yes
to drop the connection when
Ctrl-D
or
Hex 04
is detected.
Both
Telnet Com Port Cntrl
and
Check EOT
(Ctrl+ D)
must be enabled for
Disconnect with EOT
to function
properly.
Ctrl+D
is only detected going from the serial port to the
network. The default setting is
No
.
Inactivity Timeout
Use this parameter to set an inactivity timeout. The unit drops the
connection if there is no activity on the serial line before the set time
expires. Enter time in the format mm:ss, where m is the number of
minutes and s is the number of seconds. To disable the inactivity
timeout, enter
00:00
.
3. When you are finished, click the
OK
button.
4. On the main menu, click
Apply Settings
.
Connection Settings - UDP
To configure a channel’s UDP settings:
1. On the main menu, click
Connection
. The Connection Settings window for the selected
channel displays.
2. In the available fields, enter or modify the following information:
Figure 1-8 UDP Connection Settings